Design code | • "Design and Construction of Large Welded Low-Pressure Storage Tanks" (API 620), | |
• "Design and Manufacture of Site Built, Vertical, Cylindrical Flat-bottomed Steel Vessels for the Storage of Cryogenic Liquefied Gas" (GB/T26978-2021), | ||
• "Storage Tank Systems for Refrigerated Liquefied Gas" (API 625) | ||
• "Welded Tanks for Oil Storage" (API 650) | ||
Function | Storage Cryogenic liquid | |
Type | Double layer metal wall | |
Storage Medium | LNG | |
Structure | Full containment | |
Insulation Type | perlite + elastic felt + cellular glass insulation block + glass wool | |
Design Pressure (MPa) | 25/-0.5kPa | |
Design Temperature | Primary container | -196ºC/50ºC |
Secondary container | -196ºC/50ºC | |
The Main Material | Primary container | S30408/SA-240 304 |
Secondary container | S30408/SA-240 304 | |
Working Pressure | 15kPa or customized | |
Effective Volume | 5000 | |
Static evaporation rate | ≤ 0.08% /d(LNG) | |
Design service life | 20 years | |
Painting | Primer coat (Prefabricated)+ intermediate coat + topcoat (on-site) | |
Color | Customized / Standard [white] | |
Mode of transportation | Road, Sea or Railway | |
Core Components | Primary container, Secondary container, Thermal corner protect layer, Insulation system, Pipeline, Tower ladder & steel structure, Valves & Instruments, Firefighting system. |
1.With high safety and sealing, it can ensure the safety of storage and prevent accidents, widely used in petrochemical and other fields.
2.The primary and secondary container are both flat-bottomed and cylindrical metal storage tanks, and the primary container top is deck type. It is suspended from the vault support structure of the secondary container through a boom. The top of the secondary container is a spherical arch, and the top support structure is a ribbed ring grid. The foundation of the LNG storage tank adopts a concrete elevated pier structure.
3.The following are safety measures to prevent overpressure:
1)Recycle the evaporated gas from the tank via the BOG pipe;
2)Discharge the gas from the tank to a low-pressure flare through the vent line;
3) The exhalation relief valve actuates to vent gas from the tank to the low-pressure flare;