Extraordinary performance points
*12.1 inch touch screen with desirable color schemes.
*The simplest interface boots a precise control and convenient operation.
*Applied for adult.pediatric and infant.
*Multi-mode ventilation function (VCV, SIMV, SIMV/PSV, PSV, PCV, APNEA, CPAP, BIPAP, APRV, Manual, SIGH).
*Applied with Invasive ventilation and Non-invasive ventilation.
*Advanced air compressor for air input.
*Self testing and calibration function.
*Design of intelligent flashing alarm indicator(Priority alarm, secondary alarm).
*Auto-wash for exhaust valve.
*Assistant Nebulization treatment, High flow oxygen therapy, Auxilary suction.

Specifications
Specifications
| Physical Specifications | |
| Dimensions | 45*55*140cm |
| Weight | 65kg |
| Casters | Front wheels with lock |
| Screen | 12.1 inch touch screen |
| Display | Colour LCD |
| Display graphics | Waveforms of P-T,F-TV-T |
| Loops | P-V,F-V,F-P |
| Pipeline Supply | |
| Gas configuration | O2, Air |
| Pipeline input range | 280-600kPa |
| Air Compressor Specifications | |
| Power | AC220V+10%50Hz+2% |
| Output pressure | 0.4+0.1MPa |
| Noise | ≤50dB |
| Battery Power | |
| Battery Type | Lead-acid 12V.4Ah |
| Run-time | Typical 180 mins+ |
| Modes of Ventilation | VCV,APNEA,SIMV,SIMV/PSV,MANUAL,CPAP,PSV,PCV,BIPAP,SIGH,ARPV,NIV |
| Ventilator Parameter | |
| Tidal Volume range | 20-2000ml |
| Pressure range | 5-80 cmHz0 |
| Respiration Rate Range | 1-100bpm(1-40bpm under SIMV) |
| Inspiration time | 0.2-12s |
| Pressure control/Pressure support | 0-80cmH2O |
| Inspiration plateau | OFF1-50% |
| SIGH | OFF1-5/100 |
| Oxygen concentration | 21%-100% |
| Ptrigger Range | -20-20cmH20(bassed on PEEP) |
| Ftrigger Range | 0.3-30L |
| PEEP | |
| Type | Integrated,Electronic control |
| Range | OFF,3-40cmH2O |
| Parameter monitoring | |
| Vti,Vte,Ppeak,Pmean,Pplateau,PEEPNIF,FlowlMax,FlowEMax,FrepT,FrepSp, | |
| FrepM,MVsp,MVleak,Vtrdeep,Ptrideep,RVR(RSBI),Ri,Rex,Cs,Cdyn,WOB,RCexp, | |
| FiO2,CO2(Optional) | |
| Alarm Limits | |
| Visual/Audio | No tidal volumeMVPaw,FiO2 limitationO2,Air failure,AC power failure,backup low |
| Pre-setting Functions | |
| Language | English |
| Self-test | AUTOMATIC |
| Typical function | |
| Auxiliary Suction function | Optional |
| O2 remedy | Up to 60 L/min **Optional** |
| Nebulization | |
| Environmental Conditions | |
| Operating Temp | 5ºC~40ºC |
| Storage Temp | -10ºC~+40ºC |
| Humidity | ≤80% |
| Atmosphere pressure | 960hPa~1040 hPa |
Certificates