Arc Fault Protection Preventing (AFDD) Protection Fire Prevention by Arc Monitoring

Price $32.50 Compare
Min Order 500 Pieces
Availability In Stock
Shipping From Zhejiang, China
Popularity 289 people viewed
Quantity
+-
 

Wenzhou Santuo Electrical Co., Ltd.

VIP   Audited Supplier 9 years
Profile Certified by SGS/BV
SKL9-63
Low Voltage Circuit Breakers
Electric Type
Normal Type Circuit Breaker
Air
Fixed
ELCB
4
Circuit Breaker
Circuit-Breaker Failure Protection
ISO9001-2000, CE
Afdd
2p 4p
up to 40A ;up to 63A
230V, 380V
50Hz, 60Hz, 50/60Hz
SONTUOEC, WZSTEC
Exporting Carton
100pcs/ctns
Wenzhou Zhejiang, China
8536200000
Product Description
Product Description

 

Arc Fault Detection Device - AFDD
The AFDD provides a full protection solution against electrical ignited fires

The AFDD provides a full protection solution in one device that enhances consumers' peace of mind against fires ignited by electrical installations, while adding additional comfort. This all-in-one device gives the consumer full protection in his home and enables the installer to offer and install products that comply with new codes and standards.
Mostly these devices are intended for residential applications (bedrooms, nurseries), hospitals, assisted living, nursery schools, where the residents might have difficulties to evacuate, because they are immobile, sleeping or unaware of a the threat. As well Shopping centres, airports, train stations such applications, where large groups of people have to be evacuated in case of fire. It is recommended to use an AFDD as well in buildings where valuable assents need to be protected, like a museum or a library.
 
Model Name SKL9-40 ;SKL9-63  AFDD
Standard IEC62606 ;IEC61009-1
Poles 2P 4P
Rated current In(A) up to 40A ;up to 63A
Rated voltage Un(V) 230V, 380V
Frequency of coil 50Hz, 60Hz, 50/60Hz
                      Breaking capacity(Ka) 6KA


Conventional circuit breakers do not afford reliable protection against arc faults. That is because they are not designed to detect sudden dangerous arcs. They ensure protection against short circuits and overloads.

And even if you are careful to keep cords out of harm's way and to use only certified plugs and adapters, arc fault conditions may build up out of sight. In all homes your power use alternates between periods of peak and standby consumption. Such patterns of such puts a strain on cables and connections, wearing out the insulation and loosening wires. As a result, weak points form in your installation. That's where electrical arcs occur.
And you have no way of knowing. Until it's too late. Unless, that is, you have an arc fault detection device.

What is an arc fault detection device?

Arc Fault Detection Devices (AFDDs) are devices that protect specifically against arc faults. They automatically trip a circuit when they detect dangerous electric arcs.

They are compact, modular devices that are easily installed in electrical panels along with other protective equipment. Each AFDD is designed to protect an electric, instantly detecting any dangerous arc. You should install AFDDs on the electrical circuits most exposed to risk - e.g. the final circuits that supply socket outlets.

Can arc fault detection devices distinguish between dangerous and working arcs?

Yes. Arc fault detection devices are extremely sensitive and designed to sense and respond only to potentially dangerous arcs. They use a special algorithm to distinguish between dangerous and working arcs - i.e. the harmless sparks that you see when you flick a switch or pull a plug.
This is important as over-sensitive AFDDs could be prone to nuisance tripping - e.g. interrupting a circuit when it senses the slightest harmless arc.

How do arc fault circuit breakers work?

AFDDs constantly monitor and analyse patterns in electrical current and voltage waveforms. They are on the look-out for the random, non-predictable yet persistent patterns of waveform that denote a potentially dangerous arc.
When it senses a potentially dangerous wave pattern, it trips, thus isolating the faulty circuit. An AFDD can work in conjunction with a "circuit-breaker" or residual-current circuit breaker with overload protection (RCBO). It may also incorporate its own switching function.

AFDDs react very fast to the slightest change in wave patterns. Speed is of the essence as an electrical arc can degrade in a flash (literally), igniting any nearby inflammable material and causing a fire.

Why aren't AFDDs a standard requirement?

They are, but not everywhere. They have long been used in the aviation industry, for example. It is only recently, however, that they have drawn attention as safety equipment in homes and buildings.

Several countries have made arc fault detection devices part of their national installation rules. Two of them are the US and Canada, where AFDDs are known as arc fault circuit interrupters (AFCIs). Devices themselves must comply with AFDD product standards, while installation rules govern their placement and installation.

Please feel free to post your comments and questions on this new technology.

FAQ
Q 1. what's the payment term?  
A. We accept TT,30% deposit and 70% balance agaisnt copy of BL
Q 2. how's the delivery time ? 
A. usually it will take about 25 days for production
Q 3. tell me the standard of package?  
A. Normally are cartons, but also we can pack it according to your requirement.
Q 4.Would you accept to use our logo ? 
A.If you have good quantity,it absolute no problem to do OEM.
Q5. Can i take some samples?
A: Yes, we support to take samples before place the order. Just feel free to contact with us if you have any requirements.
Q6. Are you original Factory?
A: Yes, we have our own factory .
Q7. How can you make sure the quality of the products?
A: We will accord to international quality standards to inspect every item before leaving our factory.

  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$0.76 2000 Pieces(MOQ)

220V 16A 32A Industrial Socket Electrical IP44, IP67 3pin Plugs

Wenzhou Santuo Electrical Co., Ltd.
$1.95 1000 Pieces(MOQ)

AC Contactor Gmc Contactor, 3 Phase Electricity Gmc Brand AC Contactormagnetic Contactors

Wenzhou Santuo Electrical Co., Ltd.
$3.45 1000 Pieces(MOQ)

2p 63A 30mA RCCB Circuit Breaker Residual Current Device RCD

Wenzhou Santuo Electrical Co., Ltd.
$2.15 1000 Pieces(MOQ)

Sontuoec Str2-D Series (STR2-D23) Overload Thermal Relay for Cjx2/LC1-D Contactor

Wenzhou Santuo Electrical Co., Ltd.
Negotiable 9 Pieces(MOQ)

Power substation APG Pole for 40.5kv Vep326A

Wuhan Feite Electric Co., Ltd.
$1500.00 1 Piece(MOQ)

Outdoor High Voltage Vacuum Circuit Safetydc 69kv 145 Kv 250A Safety Disconnect Switch

Fenarro Power Technology Co., Ltd.
$8.89 1 Piece(MOQ)

Korlen RCCB Photovoltaic Leakage Protection Device 63A CE CB Certificates

Gaonenggele Electrical Shares Co., Ltd.
$720.00 1 Piece(MOQ)

Factory Price Zn63 (vs1) -24 Types 12kv 24kv Vcb High /Medium Voltage 630A 1250A Vacuum Circuit Breaker Hv Vcb Mechanism for Switchgear

Shengsu Electric Co., Ltd.
$25.00 1 Piece(MOQ)

Ah63-24 Hv Vacuum Circuit Breaker

ANHUANG ELECTRIC POWER TECHNOLOGY CO., LTD.
$1500.00 1 Piece(MOQ)

11kv 12kv High Voltage Indoor Vcb Handcart Type Vacuum Circuit Breaker

Shanghai Kaiji Power Equipment Co., Ltd