Custom Transformer Lightning Surge Impulse Voltage Generators for Test

Price $70000.00 Compare
Min Order 1 Piece
Availability In Stock
Shipping From Hubei, China
Popularity 345 people viewed
Quantity
+-
 

Sansion Power Electric Co., Ltd.

VIP   Audited Supplier 11 years
Profile Certified by SGS/BV
SXCF
Onsite and Video Call Remote Guidance
2 Years Free Warranty Long Life Service
LCD
Computer Control
0-100Kg
380V/220V110V at Cutomized
10kj or at Customized
200kv or at Customized
0.5UF or at Customized
100kv 0.25UF or at Customized
50Hz
Above 8 Hours
Sansion
Plywood Case
ISO9001 SGS
Wuhan, China
9030339000
Product Description


 Impulse Voltage Generator for  Lightning Test

General Information:
This impulse test system is used for carrying out standard lightning impulse voltage full wave and operation wave tests on HV apparatus such as power capacitors, clearance, bushings, power transformers and CT/PT at 10kV or below.

Main Parameters for System

Nominal voltage: ±200kV

Impulse capacitance: 0.5µF
 
Number of stages: 2

Rated stage voltage: ±100kV

Rated energy: 10kJ

Rated stage capacitance: 1µF(each impulse capacitor 1µF at 100kV, total 2pcs)

Impulse voltage waveform: generated when load capacitance is 300-3000pF.T1=1.2µs±30%, T2=50µs±20%, standard lightning impulse voltage full waveform of peak voltage deviation≤3%;
Standard operation waveform 250±20%/2500±60%. These 2 Impulse voltage waveform parameters and error are accorded with national requirements of GB311.1and GB16927.1 standard and IEC standard.

Voltage utilization factor: Standard lightning impulse voltage waveform ≥90% when load capacitance is below 1000pF, standard operation impulse voltage waveform≥80% when load capacitance is below 2000pF. Standard operation impulse voltage waveform ≥70%.

Locking range: level voltage is within the range of 20%-100% rated voltage, positive and negative locking range no less than 25%.

Out-of-control rate of synchronous discharge: <5%

Min. output voltage: ≥±20% of rated voltage.

Instability of discharge voltage: <±1.0%

Continuous time: Above 2/3 of rated voltage, continuous working when charge and discharge once every 120s. Below 2/3 of rated voltage, continuous working when charge and discharge once every 60s.

Above information for reference using, please contact us for further technical details.

Impulse Voltage Generator

More details please contact Sansion Power by email for further information.

  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$25000.00 1 Set(MOQ)

50kVA Transformer Induced Voltage Withstand Test System (DVDF)

Sansion Power Electric Co., Ltd.
$70000.00 1 Piece(MOQ)

Custom Transformer Lightning Surge Impulse Voltage Generators for Test

Sansion Power Electric Co., Ltd.
$6000.00 1 Set(MOQ)

Transformer Winding Resistance Meter DC Tester

Sansion Power Electric Co., Ltd.
$100000.00 1 Set(MOQ)

Fully Automatic Variable Frequency AC Motor Test System of Capacity 630kw-9000kw

Sansion Power Electric Co., Ltd.
Negotiable 1 Piece(MOQ)

Automatic Fatigue and Endurance Testing Machine with Ce Certificate

Suzhou Tophung Machine Equipment Co., Ltd.
$2000.00 1 Piece(MOQ)

Cmt CCT Concora Medium Fluter, Fluting and Test Liner Corrugated Crush Concora Crush Tester, Paper Test Equipment Factory

Jinan Xinghua Instruments Co., Ltd.
$37000.00 1 Piece(MOQ)

Friction Material Testing Machine Chase Tester (SJ160)

Jilin Songjiang Tech-trade Co., Ltd.
$15000.00 1 Set(MOQ)

Turbinol Turbine Oil Filtering/Purification Machine Impurity Removal, Water Removal and Degassing Filter

GOLDSOL(WUHAN)HIPOT TEST EQUIPMENT FACTORY
$2150.00 1 Piece(MOQ)

NTD Ultrasonic Metal Detector Quality Ultrasonic Flaw Detector

Shenzhen Taijin Precision Instrument Co., Ltd
$10000.00 1 Set(MOQ)

Tan Delta Test/Loss Angle Test/Dissipation Factor Test

Sansion Power Electric Co., Ltd.