Custom Transformer Lightning Surge Impulse Voltage Generators for Test

Price $70000.00 Compare
Min Order 1 Piece
Availability In Stock
Shipping From Hubei, China
Popularity 359 people viewed
Quantity
+-
 

Sansion Power Electric Co., Ltd.

VIP   Audited Supplier 11 years
Profile Certified by SGS/BV
SXCF
Onsite and Video Call Remote Guidance
2 Years Free Warranty Long Life Service
LCD
Computer Control
0-100Kg
380V/220V110V at Cutomized
10kj or at Customized
200kv or at Customized
0.5UF or at Customized
100kv 0.25UF or at Customized
50Hz
Above 8 Hours
Sansion
Plywood Case
ISO9001 SGS
Wuhan, China
9030339000
Product Description


 Impulse Voltage Generator for  Lightning Test

General Information:
This impulse test system is used for carrying out standard lightning impulse voltage full wave and operation wave tests on HV apparatus such as power capacitors, clearance, bushings, power transformers and CT/PT at 10kV or below.

Main Parameters for System

Nominal voltage: ±200kV

Impulse capacitance: 0.5µF
 
Number of stages: 2

Rated stage voltage: ±100kV

Rated energy: 10kJ

Rated stage capacitance: 1µF(each impulse capacitor 1µF at 100kV, total 2pcs)

Impulse voltage waveform: generated when load capacitance is 300-3000pF.T1=1.2µs±30%, T2=50µs±20%, standard lightning impulse voltage full waveform of peak voltage deviation≤3%;
Standard operation waveform 250±20%/2500±60%. These 2 Impulse voltage waveform parameters and error are accorded with national requirements of GB311.1and GB16927.1 standard and IEC standard.

Voltage utilization factor: Standard lightning impulse voltage waveform ≥90% when load capacitance is below 1000pF, standard operation impulse voltage waveform≥80% when load capacitance is below 2000pF. Standard operation impulse voltage waveform ≥70%.

Locking range: level voltage is within the range of 20%-100% rated voltage, positive and negative locking range no less than 25%.

Out-of-control rate of synchronous discharge: <5%

Min. output voltage: ≥±20% of rated voltage.

Instability of discharge voltage: <±1.0%

Continuous time: Above 2/3 of rated voltage, continuous working when charge and discharge once every 120s. Below 2/3 of rated voltage, continuous working when charge and discharge once every 60s.

Above information for reference using, please contact us for further technical details.

Impulse Voltage Generator

More details please contact Sansion Power by email for further information.

  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$10000.00 1 Set(MOQ)

Insulation Glove Integrity Pressure Leakage Current Tester Dielectric Gloves Boots Testing Machine

Sansion Power Electric Co., Ltd.
$100000.00 1 Set(MOQ)

Manufacturer Price High Voltage Primary Current Injection Set 1000A Primary Injection Test Systems

Sansion Power Electric Co., Ltd.
$70000.00 1 Piece(MOQ)

200kv 10kj Impulse Voltage Generator/Test System Surge Voltage Generator

Sansion Power Electric Co., Ltd.
$70000.00 1 Set(MOQ)

Transformer Test Bench AC High Voltage Withstand Test Set (HV Test)

Sansion Power Electric Co., Ltd.
$4999.00 1 Piece(MOQ)

Is075 ASTM D 648 Thermal Deformation Vicat Softening Point Hdt Vicat Apparatus

Guangdong Guangce Instrument Technology Co., Ltd.
$2000.00 1 Set(MOQ)

Pn-48b ISO Brightness Tester

Hangzhou Pnshar Technology Co., Ltd.
$30000.00 1 Set(MOQ)

Reliable Vibration Testing Equipment for Aerospace and Automotive Parts

Ai Si Li (China) Test Equipment Co., Limited
$2500.00 1 Set(MOQ)

3 Phase Relay Tester Customized Line Voltage Current Injection Test Set

Wuhan Huayi Electric Power Technology Co., Ltd.
$26740.00 1 set(MOQ)

IEC 61215 Standard Solar Panel Impact Testing Machine

Dongguan Hong Tu Instrument Co., Ltd.
$8200.00 1 Piece(MOQ)

ISO 5084 THK-01 Thickness Gauge for Plastic Film Sheet Paper China Price

Pubtester Instruments Co., Ltd.