Material: Medical-grade titanium
Features
- Made from high-strength medical-grade titanium, ensuring durability and biocompatibility.
- Compatible with HA 3.5 mm and locking screws 2.7/3.5 mm for multi-level fixation.
- Polished and anodized surface treatment for enhanced corrosion resistance and reduced tissue irritation.
- Anatomically pre-contoured to fit the distal anterolateral tibia, ensuring optimal fracture alignment.
- Available in left and right configurations to accommodate both tibial orientations.
Intended Use
The Distal Anterolateral Tibial Universal Locking Plate (L/R) is designed for the treatment of fractures located in the distal anterolateral tibia, particularly for cases requiring rigid fixation using locking screws.Indications
- Distal tibial fractures involving the anterolateral aspect
- Nonunion or malunion of distal tibia
- Complex fractures requiring locking plate fixation
- Osteotomies involving the anterolateral tibial region
Contraindications
- Active infections in the surgical area
- Severe osteoporosis or poor bone quality
- Known allergic reactions to titanium materials
- Patients with insufficient bone stock for stable fixation
Product Parameters Table for Distal Anterolateral Tibial Universal Locking Plate (L/R)
Parameter | Details |
Product Name | Distal Anterolateral Tibial Universal Locking Plate (L/R) |
Material | Medical-grade titanium |
Surface Treatment | Polished and anodized for corrosion resistance and minimal tissue irritation |
Plate Type | Universal locking plate for distal anterolateral tibial fractures |
Available Versions | Left and right configurations available |
Holes Configuration | 4, 6, 8, 10, 12, 14, 16 holes |
Length (mm) | 82 mm, 112 mm, 142 mm, 172 mm, 202 mm, 232 mm, 262 mm |
Screw Compatibility | HA 3.5 mm, Locking screws 2.7/3.5 mm |
Indications | Distal anterolateral tibial fractures, osteotomies, nonunion fractures |
Contraindications | Active infection, poor bone quality, allergies to titanium |
Sterilization Method | Supplied unsterile, requires sterilization before surgery |
Fixation Type | Rigid fixation using locking screws |
Intended Surgical Approach | Open reduction and internal fixation (ORIF) for distal tibial fractures |
Packaging | Non-sterile packaging, requires sterilization before use |
CE Certification | Certified for use in multiple international markets (CE compliant) |
Shelf Life | 5 years when stored under appropriate conditions |
Radiolucency | Radiolucent for use with imaging modalities like X-ray and CT |
Customization | Available in different lengths and configurations for patient-specific needs |
Usage Environment | Designed for sterile operating room conditions |