Drh300 Insulation Material Heat Flow Meter for Thermal Conductivity Measurement Test Equipment

Price Negotiable Compare
Min Order 1 Set
Availability In Stock
Shipping From Hunan, China
Popularity 355 people viewed
Quantity
+-
 

Hunan Zhenhua Analysis Instrument Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
DRH300
1 Year
1 Year
0 - 40c, Rt - 100 C, -20 C - 70c
300*300*100mm
ISO8301, ASTM C518, DIN En 12667
Hunan Zhenhua
Standard Exporting Wooden Case
1CBM
China
9031809090
Product Description
Product Description

DRH300 Series Precision heat flow meter for thermal conductivity measurement

Heat flow method is the world recognized insulation standard test method, thermal heat conduction device use double heat flux sensor, excellent temperature stability, heat conduction coefficient 0.005...0.5 W/(m * K), used in building materials, filling materials, powder materials, gypsum board, fibreboard and rubber and other fields. DRH300 is protect heat plate thermal conductivity apparatus, coefficient of thermal conductivity range 0.007...2.0 W/(m * K), its application field is similar to the heat flow method, is characterized by wide temperature range. Protect heat thermal conductivity meter is suitable for measuring the medium coefficient of thermal conductivity of solid materials, thermal conductivity range 0.1...10 w/(m * K), fast measuring speed, wide measuring range, used in plastics, rubber, sealing materials, ceramic, molten metal and circuit board materials and other fields.
Main features:
DRH300 series thermal conductivity meter is based on the steady-state method, is able to measure 30 cm x 30 cm samples, thickness ranging from a few millimeters to 10 (20)cm. All testing functions automatically; Motor control of the plate movement; Measurement set up and run very fast; Sample sandwiched between two heat flux sensor test, fixed or adjustable temperature gradient. In a few minutes after stability of temperature and temperature gradient, using the embedded controller or external computer measured the thermal conductivity and thermal resistance of the sample. Automatic upper plate move and sample thickness measurement, simplifies the test preparation. All test parameters and the correction data can be stored in the computer. Suitable for industrial applications, superior performance. DRH300 coefficient of thermal conductivity measurements conform to ASTM C 518, ISO 8301, JIS b 1412, DIN EN 12939, DIN EN 13163 with DIN EN 12667 and relevant international standards.
 
Product Parameters

Technical parameters:

      Model
Specifications
DRH300ADRH300BDRH300C
Average temperature range0 ~40 ºC variableRT ~ 100 ºC variable-20 ~ 70 ºC variable
Cooling systemexternal water bathexternal water bathforced air cooling
plate temperature control systemPeltier systemPeltier systemPeltier system
programmable data points101010
Sample size(mm)300×300×(10-100)300×300×(10-100)300×300×(10-100 )
Thermal resistance range0.1 ~ 8.0 m2K/W
Coefficient of thermal conductivity range0.005~ 2.0 W/m K
Repeatability1%1%1%
Accuracy+ / - 1% ~ 3%
Shape dimension reference79×63×77 cm94×72×88 cm79×63×77 cm
 
Detailed Photos

 




Assembly and commissioning

 


 
Our services

 
Company Profile


  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
Negotiable 1 Set(MOQ)

Thermoelectric Measurement Seebeck Coefficient Instrument

Hunan Zhenhua Analysis Instrument Co., Ltd.
Negotiable 1 Set(MOQ)

Sanitary Ceramics Toilet Flushing Function Comprehensive Testing Machine

Hunan Zhenhua Analysis Instrument Co., Ltd.
$2000.00 1 Set(MOQ)

Jb-30 Ceramic Tableware Impact Resistance Tester

Hunan Zhenhua Analysis Instrument Co., Ltd.
$1500.00 1 Piece(MOQ)

Pk-500n/1000n Manual Digital Display Ceramic Billet Bending Tester

Hunan Zhenhua Analysis Instrument Co., Ltd.
$2500.00 1 Piece(MOQ)

Laboao Aflatoxin Testing Device Ensuring The Safety of Corn Peanuts and Grains

Zhengzhou Laboao Instrument Equipment Co., Ltd.
$7000.00 1 Piece(MOQ)

Fluorescent Indicator Absorption Apparatus

Liaoning Huake Petroleum Apparatus Science & Technology Co., Ltd.
$5000.00 1 set(MOQ)

Automatic Ceramics Thermal Shock Resistance Testing Machine

Hunan Zhenhua Analysis Instrument Co., Ltd.
$53000.00 1 Set(MOQ)

Spectrometer Metal Analysis for Stainless Steel

WUXI JINYIBO INSTRUMENT TECHNOLOGY CO., LTD.
Negotiable 1 Piece(MOQ)

Automatic Cleaning Online Cod Toc BOD Controller for Water Plant

Suzhou Delfino Environmental Technology Co., Ltd.
$6111.00 1 Set(MOQ)

ASTM D92 SYD-3536D Automatic Cleveland Open Cup Flash Point Tester for Oil Testing

Shanghai Changji Geological Instrument Co., Ltd.