Circuit Diagram:
(1) Current signal:
Built-in terminal, two-wire system, regardless of positive and negative poles
(2) Voltage signal:
Defined according to customer requirements
Specification:
| Parameter | Value | Unit |
| Rated load (Emax): | 50~200 | kN |
| Rated output(Cn): | 2.0±0.1% | mV/V |
| Combined error: | 0.5 | ±% of rated output |
| Temperature effect on sensitivity(Tkc): | 0.5 | ±% of rated output/ºC |
| Temperature effect on zero balance(Tk0): | 0.5 | ±% of rated output/ºC |
| Zero balance: | 1.0 | ±% of rated output |
| Input resistance(Rlc): | 2000 | Ω(ohms) |
| Output resistance(Ro): | 2000 | Ω(ohms) |
| Insulation resistance: | ≥5000 | MΩ(Mega-Ohms) |
| Safe overload: | 150 | ±% of rated capability |
| Ultimate overload: | 200 | ±% of rated capability |
| Operating temperature range: | -30~+70 | ºC |
| Recommend excitation: | 5~12(Voltage type) /15~24(Current type) | VDC |
| Maximum excitation: | 15(Voltage type) /36(Current type) | VDC |
| Material of elastomer: | Stainless steel | |
| Protection class: | IP68 | |
Ningbo GEANTEC Electronic Co., Ltd., the overseas department of SMNOON Technology Development Group, is a professional supplier of oilfield IoT equipment, weighing solutions, and force measurement with 37 years of experience.
GEANTEC main products:
- Oil well IoT: oilfield testing instruments, digital remote measuring and control systems, portable oil well diagnostic instruments, industrial RTUs, and industrial automation control cabinets.
- Weighing solutions: weighing load cells, indicators, and weighing systems.
- Force measurement: force load cells, pressure transducers, and angle transducers.













Audited Supplier