Features:
1. AC input range selectable by switch
2. Protections: Short circuit / Overload / Over voltage / Over temperature
3. 100% full load burn-in test
4. Low cost, high reliability
5. 24 months warranty
| Model | EDR-120-12 | EDR-120-15 | EDR-120-24 | EDR-120-48 |
| DC output voltage | 12V 0~10A | 15V 0~8A | 24V 0~5A | 48V 0~2.5A |
| Wave and noise | 100mVp-p | 120mVp-p | 120mVp-p | 150mVp-p |
| Inlet wire stabilily | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load stability | ±1% | ±0.5% | ±0.5% | ±0.5% |
| Efficiency | 85% | 87.5% | 87.5% | 88.5% |
| Adjustable range for DC voltage | ±10% | ±10% | ±10% | ±10% |
| Input voltage range | 85~264VAC 120~370VDC 47~63Hz | |||
| Impact current | Cold start current 20A/115VAC 40A/230VAC | |||
| Overload protection | 105%~150% cut off the output, automatic recovery | |||
| Over voltage protection | 120%~140% shut down O/P voltage, re-power on to recover | |||
| Setup, rise, hold up time | 1200ms, 60ms, 60ms/230VAC at full load | |||
| Withstand voltage | I/P-O/P: 1.5kV I/P-FG: 1.5kV O/P-FG: 0.5kV 1 minute | |||
| Isolation resistance | I/P-O/P I/P-FG O/P-FG: 500VDC/100MΩ | |||
| Working temperature | -10ºC~+50ºC | |||
| Dimension | 40 x 125.2 x 113.5mm | |||
| Weight | 0.6kg | |||
| Packing | 45.5 x 35 x 26CM | |||









Audited Supplier