Fast Delivery for Sodium/Lithium Heparin Tubes Blood Sample Collection Vacuum Tubes
Product introduction:
Heparin Tubes are coated with Lithium Heparin or Sodium Heparin to inhibit clotting. Sodium Heparin or Lithium Heparin Tubes are used to produce plasma for biochemical testing. The Heparin Tubes are also available with Gel separator. The range of application is: clinical chemistry and trace mineral testing.
Product Features:
Specification:13*75mm,13*100mm,16*100mm
Volume:1.6ml,2ml,3ml,4ml,5ml,6ml,7ml,8ml,10ml
Additive: lithium heparin/sodium heparin/3.2%sodium rate/3.8% sodium citrate
Certificate:CE&ISO13485 certificate approved
Packing:100pcs/foam tray,1200pcs or1800pcs tubes/carton

-Green cap.contains heparin sodium/lithium for clinical biochemical tests. The inner wall of the tube is evenly sprayed with anticoagulant drugs, which can be used as the main blood collection tube in laboratories that do not require a separation tube but require plasma samples.
-pet tube material, pe cap
All Specifications for the blood collection tubes:
Packing Information:
Specification | Material | Quantity | Packing Size | Gross Weight |
13*75mm | PET | 1200pcs | 52.8*29.5*18.5cm | 8.05kg |
13*100mm | PET | 1200pcs | 52.8*29.5*23.3cm | 10kg |
16*100mm | PET | 1200pcs | 61*33.5*23cm | 12.5kg |
Step 1: Place patient's arm in a downward position and clean venipuncture site with alcohol;
Step 2: Apply tourniquet;
Step 3: Remove the upper cover of needle and assemble the needle in holder; Perform venipuncture with arm downward and tube stopper upper-most;
Step 4-5: Push tube onto needle, puncturing stopper diaphragm;
Step 6: Release tourniquet as soon as blood appears in tube and remove tube from holder when first tube has filled to its stated volume and blood flow ceases;
Step 7: Turn the filled tube upside-down and return it to upright positions and repeat this inversion according to different additive performance;
Step 8: Place succeeding tubes in holder, puncturing diaphragm to begin follow, see Recommended Order of Draw;
Step 9: As soon as blood stops flowing in the last tube, remove tube from holder and remove needle from Vein, applying pressure to puncture site with dry sterile swab until bleeding stops;
Step 10: Dispose the needles into Sharps Disposal Containers according to related policies and guidelines.
Certificates:

Company Information:
Changsha Renji Medical Equipment Co.,Ltd is a medical supply company specilizing in products series, such as disposable virus specimen collection sampler and Saliva collection kits for PCR test. Vacuum blood collection tubes and other medical consumables. We are direct manufacturer based on Changsha City Hunan Province. And many of our staffs are gene experts and professional doctors who have plenty of experience in this industry. Our products have been approved by many certificates. Such as CE, SGS,ISO and so on.