Heat Flow Method Thermal Resistance R-Value Measurement Thermal Conductivity Meter

Price Negotiable Compare
Min Order 1 Set
Availability In Stock
Shipping From Hunan, China
Popularity 509 people viewed
Quantity
+-
 

Hunan Zhenhua Analysis Instrument Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
  • Hunan, China
  • Helene Xu (Ms.)  
    Manager
DRX-II-RL
Free Remote Assistance
1 Year
Electronic
Polymer Materials, Ceramics, Insulation Materials,
Hunan Zhenhua
Standard Export Packing
0.3CBM
China
9027809990
Product Description
DRX-II-RL Thermal Resistance Measurement Thermal Conductivity Meter (Heat flow method)

 Use: This thermal conductivity meter measures the thermal conductivity, thermal diffusivity, and hot-melt of different materials by using heat flow method. Refer to standard MIL-I-49456A The thermal conductivity of thin solid electric insulation heat transfer performance testing standards, D5470-06, ASTM E1530, ASTM C 518, ISO 8301, JIS A 1412, DIN EN 12939, DIN EN 13163 and DIN EN 12667 and other relevant international standards.

Features: Automatic plate movement and sample thickness measurement, all test parameters and calibration data can be stored in the computer. Conduct temperature programming, data viewing and storage for calibration test and sample test. The instrument is used to test polymer materials, ceramics, insulation materials, composite materials, non-metallic materials, thermal pad, silicone grease, and other materials with low and medium thermal conductivity. Only small samples are needed. Thin films can be accurately measured using multilayer techniques.

Main technical parameters:
 
Hot surface temperature range:  RT~ 200ºC , resolution: 0.01 ºC
Cold surface temperature range:0~60ºC, resolution: 0.01 ºC
Refrigeration systemForced air-cooled, external water bath, liquid nitrogen cooling
Flat-panel temperature control systemsautomatic control programmable data points 1-10
Sample sizeDiameter 30mm, thickness 0.02 -20mm 
Range of Thermal resistance(r-value)0.000005 ~ 0.05 m2·K/W
Range of thermal conductivity(λ)0.015~50w/m.K
Accuracy≤±3%
Heat flow meterAdopt high precision heat flow meter imported from the United States of America
Pressure range0-1000N
Displacement range0-30.00mm
Repeatability1% 
Accuracy±3%
Environmental conditionroom temperature: 18~25ºC, humidity: 20~80%RH
Data result analysisAutomatic thermal analysis software, which can analyze and output testing parameters fast and accurately and data print out, Windows 10/ 7/XP /sp2 English
Supply voltageAC 220V±5%, power: 3.0kw
  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
Negotiable 1 Set(MOQ)

Laser Flash Thermal Diffusivity Thermal Conductivity Instrument

Hunan Zhenhua Analysis Instrument Co., Ltd.
$2400.00 1 Set(MOQ)

Ceramic Glazed Tile Surface Abrasion Tester

Hunan Zhenhua Analysis Instrument Co., Ltd.
Negotiable 1 Set(MOQ)

Fast Thermal Conductivity Tester

Hunan Zhenhua Analysis Instrument Co., Ltd.
$2500.00 1 Set(MOQ)

Dmy Friction Coefficient Skid Resistance Tester

Hunan Zhenhua Analysis Instrument Co., Ltd.
$235.00 1 Piece(MOQ)

Lab Analysis Instruments Jy-Spft Horizontal Electrophoresis Tank, Electrophoresis Intruments

Beijing JUNYI Electrophoresis Co., Ltd.
$148507.00 1 Set(MOQ)

Keysight N9040b 50 GHz Uxa Signal Analysis Testing Millimeter Wave Spectrum Analyzer

Nanjing Daoce Electronics Co., Ltd.
$620.00 1 Piece(MOQ)

Water in Crude Oil Apparatus (distillation method) (HK-8929A)

Liaoning Huake Petroleum Apparatus Science & Technology Co., Ltd.
Negotiable 1 Piece(MOQ)

500mm*400mm Stroke Non-Contact CNC Video Measuring Machine APC500

Guangdong Micro Accuracy Co.,Ltd
$1300.00 1 Piece(MOQ)

Semi Automatic Closed-Cup Flash Point Tester

Liaoning Huake Petroleum Apparatus Science & Technology Co., Ltd.
$1250.00 1 Piece(MOQ)

Intelligent Chlorine Residual Analyzer with pH and Temperature Monitoring

Santo (China) Limited