Model | HP80M5 | HP110M5 | HP150M5 |
Installation | Vertical wall-hung/ducted | Vertical wall-hung/ducted | Vertical wall-hung/ducted |
Tank volume(L) | 82 | 102 | 149 |
Rated voltage/frequency(V/Hz) | 220-240V/50Hz | 220-240V/50Hz | 220-240V/50Hz |
Tank rated pressure(bar) | 8 | 8 | 8 |
Extra exchanger design/area | No | No | No |
Corrosion protection | Magnesium anode | Magnesium anode | Magnesium anode |
Water proof grade | IPX4 | IPX4 | IPX4 |
Assembled System | |||
Electric backup power(W) | 1200 | 1200 | 1200 |
Average input-heat pump only(W) | 240 | 240 | 240 |
Maximum input-heat pump only(W) | 350 | 350 | 350 |
Maximum power input(W) | 1550 | 1550 | 15500 |
Default temperature setting(°C) | 55 | 55 | 55 |
Temperature setting range with heater(°C) | 35-75 | 35-75 | 35-75 |
Temperature setting range heat pump only(°C) | 35-65 | 35-65 | 35-65 |
Refrigerant type/Weight (kg) | R134A/0.45 | R134A/0.45 | R134A/0.46 |
Ozone Depletion Potential(ODP) | 0 | 0 | 0 |
Global Warming Potential (GWP) | 1430 | 1430 | 1430 |
Noise power dB(A) | 50 | 50 | 50 |
Working temperature-heat pump only(°C) | -7-45°C | -7-45°C | -7-45°C |
Working temperature-system(°C) | -7-45°C | -7-45°C | -7-45°C |
Performance | |||
Type of extraction | Exterior | Exterior | Exterior |
COP@7°C(EN16147) | 2.86 | 2.74 | 3.14 |
COP@14°C(EN16147) | 3.17 | 3.19 | 3.58 |
Heating up time (h)(@7°C) | 4h58 | 6h35 | 10h29 |
Heating up time (h)(@14°C) | 4h09 | 5h23 | 8h28 |
Tapping cycle (EN16147) | M | M | L |
Standby power input/ Pes(W)(@7°C) | 20 | 20 | 21 |
Maximum volume of usable hot water(L)V40(EN16147) | 109 | 137 | 193 |
Water heating energy efficiency class (ERP) | A+ | A+ | A+ |
Dmensions and connections | |||
Water outlet connection | G1/2"M | G1/2"M | G1/2"M |
Water intlet & Drain connection | G1/2"M | G1/2"M | G1/2"M |
Safety valve connection | G1/2"M | G1/2"M | G1/2"M |
Product Dimensions (D*W*H mm)(tank unit/external unit) | 492*537*1170 | 492*537*1320 | 492*537*1680 |
Packing Dimensions (D*W*H mm)(tank unit/external unit) | 587*587*1247 | 587*587*1397 | 587*587*1764 |
Gross weight(kg) | 59 | 64 | 89 |
Net weight(kg | 51 | 55 | 67 |
Load qty.40HQ | 160 | 80 | 80 |
*The COP and noise level data was tested in Haier lab. |






DHA output temperature from 35°c to 65°c, the working temperature is from -7°c to 45°c, enjoy happy and safe shower for 365 days.
Haier focus on energy saving and its heat pump achieve the highest level of A+ in EU, also NF performance is 3 stars.


Full-divisional super conductive condenser with multiflow circuit, it can reduce the flowing resistance and lower the compressor energy consumption to get higher thermal efficiency. The contact area is bigger and fit seamlessly to the tank, which has faster heating speed.
Commercial level UMC tank, exclusive design for water heater, it has longer service life and stable heating performance.
resistant to corrosion, acid, alkali and very durable;


The user can choose vacation mode which will save cost. The heat pump will not work under vacation mode and it can automatically heat the water to 65°c one day before the vacation ends. This function can sterilize the tank and make sure the user can enjoy healthy water.

Step 2. The compressor pressurises the refrigerant gas, which causes it to increase in temperature.
Step 3.The refrigerant fluid loses further pressure and temperature by passing through the expansion valve causing it to completely return to its original state, It will be working by this recycle.
Step 4. From the condenser, the refrigerant gas transfers its heat to the water, which circulates into the home. This exchange process causes the refrigerant to cool down as it transfers the heat and forces it to return to a partial liquid state.
Smart defrost system, lower the energy consumption and increase the working efficiency.
2.Electricity cost saving
Optimized electric control solution, enjoy the low power by PV/HC.
3.Low noise
Patented ventilation structure and high efficiency fan, make sure the user can enjoy a quiet environment.
4.High class tank
Commercial class 3 layer inner tank, more durable and resistant to acid, alkali and corrosion.
5.Professional compressor
Specially designed professional heat pump compressor has service life up to 10 years and very good thermal efficiency.
6.User-friendly
Big touch screen, easy to operate and real-time display.
7.Stable system
Electronic expansion valve control system, more accurate and stable function.
8.Higher efficiency
Patented heat convection technology, full-dimensional micro channel and bottom coil heat exchanger to heat the water by whole tank. The thermal efficiency and DHW output will increase dramatically.




Q1. Who are we?
Q2. How can we guarantee quality?
Q3. What can you buy from us?
Q4. Why should you buy from us not from other suppliers?
Q5. What services can we provide?
Accepted Payment Currency: USD, EUR,JPY,CAD,AUD,HKD,GBP,CNY,CHF;
Accepted Payment Type: T/T,L/C,D/P D/A, MoneyGram, Credit Card, Western Union, Cash, Escrow;
Language Spoken: English, Chinese, Spanish, Japanese, Portuguese, German, French, Arabic, Russian, Korean, Italian