Model | HP200M3 | HP250M3 | HP250M3C |
Tank | |||
Tank volume(L) | 195 | 246 | 240 |
Rated voltage/frequency(V/Hz) | 230V/50Hz | 230V/50Hz | 230V/50Hz |
Tank rated pressure(bar) | 7 | 7 | 7 |
Extra exchanger design/area | No | No | 1m2 |
Corrosion proof | Magnesium anode | Magnesium anode | Magnesium anode |
Performance | |||
Type of extraction | Ambient/Exterior | Ambient/Exterior | Ambient/Exterior |
COP@7°C(EN16147) | 3.04 | 3.02 | 3.10 |
COP@15°C(EN16147) | 3.39 | 3.41 | 3.56 |
Tapping cycle (EN16147) | L | L | L |
Electric backup power (W) | 1500 | 1500 | 1500 |
Average input - heat pump only(W) | 495 | 495 | 495 |
Maximum input- heat pump only(W) | 625 | 625 | 625 |
Maximum power input (W) | 2125 | 2125 | 2125 |
Standby power input/ Pes(W) | 27 | 27 | 27 |
Vmax | 224 | 311 | 332 |
Heating up time (h)(@7°C) | 5h30 | 7h21 | 5h55 |
Heating up time (h)(@15°C) | 4h41 | 6h10 | 6h |
Default temperature setting(°C) | 55 | 55 | 55 |
Temperature setting range with heater(°C) | 35-75 | 35-75 | 35-75 |
Temperature setting range heat pump only(°C) | 35-65 | 35-65 | 35-65 |
Refrigerant type/Weight (kg) | R134a/0.9 | R134a/0.9 | R134a/0.9 |
Noise power dB(A) | 57 | 58 | 59 |
Working temperature-system(°C) | -7-35 | -7-35 | -7-35 |
Dmensions and connections | |||
Product Dimensions (D*W*H mm)-Tank | 600*629*1692 | 600*629*1987 | 600*629*1987 |
Packing Dimensions (D*W*H mm)-Tank | 736*695*1940 | 736*695*2250 | 736*695*2250 |
Gross weight (kg)-Tank/external unit | 103 | 116 | 132 |
Net weight (kg)-Tank/external unit | 91 | 102 | 119 |
Load qty.40HQ | 51 | 51 | 51 |
*The COP and noise level data was tested in Haier lab. |










Step 2. The compressor pressurises the refrigerant gas, which causes it to increase in temperature.
Step 3.The refrigerant fluid loses further pressure and temperature by passing through the expansion valve causing it to completely return to its original state, It will be working by this recycle.
Step 4. From the condenser, the refrigerant gas transfers its heat to the water, which circulates into the home. This exchange process causes the refrigerant to cool down as it transfers the heat and forces it to return to a partial liquid state.


Q1. Who are we?
Q2. How can we guarantee quality?
Q3. What can you buy from us?
Q4. Why should you buy from us not from other suppliers?
Q5. What services can we provide?
Accepted Payment Currency: USD, EUR,JPY,CAD,AUD,HKD,GBP,CNY,CHF;
Accepted Payment Type: T/T,L/C,D/P D/A, MoneyGram, Credit Card, Western Union, Cash, Escrow;
Language Spoken: English, Chinese, Spanish, Japanese, Portuguese, German, French, Arabic, Russian, Korean, Italian