High precision laboratory dedicated desktop PH meter digital display online water quality analyzer ORP meter
for measuring the pH value of an acidity meter is a potentiometric method. In addition to measuring the acidity of
the solution, it can also measure the electromotive force (mV) of the battery. It is mainly composed of three
parts: reference electrode(calomel electrode), indicator electrode (glass electrode) and precision potentiometer.
When measuring, the glass electrode is used as the indicating electrode, and the saturated calomel electrode
(SCE) is used as the reference electrode to form a battery.


Mode | KK-PH160 |
Display | 2.8-inch monochrome LCD display, resolution 128*64 |
Dimensions | 96x96x112mm |
Hole Size | 92x92mm |
Weight | 1.0kg |
Measure range | pH:0.00-14.00pH |
ORP:-1000~1000mV | |
-2000~2000mV(customized) | |
Accuracy | pH:±0.02pH;ORP:±lmV |
Input resistance | >1012Ω |
Temp.Comp | NTC10K:-10~60ºC accuracy :±0.3ºC |
-10~130ºCManu/Auto | |
Current output | Isolated type, 4~20mA can be set to correspond to pH/ORP and temperature |
Measure range | The maximum load is 750Ω, the output accuracy is ±0.2%FS |
Alarm function | 2 channels, capacity AC250V/3A, normally open |
Relative humidity | 10~85%RH(10~85%RH) |
Working Temp. | 0~60°ºC |
Power supply | 220VAC 50 |
24VDC |



production, sales and services of instruments.With advanced inspection instruments and equipment, professional talent team,
perfect scientific management control system, WEIHAI KUNKE has been distinguished as a leading role in industry.
We introduced advanced manufacturing technology from United States. We own a series of automation instruments with
independent intellectual property rights and advanced domestic automation instruments. Company has successively
obtained International Quality System Certification of ISO 9001-2015, Environmental Management System Certification
of ISO14001-2015, Measurement Management System Certification of ISO10012-2003 and OHSAS18001-2007
Occupational Health and Safety Management System Certification.








A:A change in temperature or a chemical reaction in the sample itself will cause a change in pH value. Therefore, the temperature should be kept as consistent as possible and chemical reactions should be avoided.
2. Q:Why does the same sample, measured on two pH meters at the same time, have inconsistent readings?
A:Due to the different correction conditions of the two pH meters (such as the correction done at different times), the measured values are different. Therefore, the pH meter should be corrected with the same buffer at the same time, and then measured at the same time.
3. Q:PH meter measurement is unstable and takes a long time. Why is that?
4 .Q:Why has the buffer deteriorated and become unusable during its validity period?
A:Buffer life refers to the shelf life of unopened use state. Once opened and used, the buffer is easy to deteriorate due to the action of various molds in the air. Note: The used buffer must not be poured back into the original bottle!
A:The calibration frequency of the electrode depends on the specific situation of electrode use, maintenance, sample nature and measurement accuracy. Calibration is recommended once a day; No more than one calibration per week. If the electrode is replaced and not used for a long time, it must be calibrated before use.
6. Q:The sample temperature is 10ºC. Does the meter show the pH value at 10ºC or 25ºC?
A:The pH meter shows the pH of the solution at the current temperature; If measure