GALIN POWDER COATING EQUIPMENT (DC04) ELECTRICAL DATA | |
Nominal input voltage | 100V-240VAC |
Frequency | 50/60 Hz |
Input power | 40 VA |
Rated output voltage(to gun) | 12~18VPP |
Rated output frequency(to gun) | About20KHZ |
Protection type | IP54 |
Temperature rang | +10ºC to +40ºC (+50ºF to +104ºF) |
Solenoid Valve Voltage | 24VDC |
Gun output voltage | 0-100KVDC |
Gun output current | 0-100μA |
GALIN POWDER COATING EQUIPMENT (DC04) PNEUMATICAL DATA | |
MAX.input pressure | 8bar |
MIN.input pressure | 5bar |
Output pressure | 0~8bar |
Max.water vapor content of the compressed air | 1.3g/m³ |
Max.oil vapor content of the compressed air | 0.1mg/m³ |
Max.compressed air consumption | 19Nm³/h |
GALIN POWDER COATING EQUIPMENT (DC04) GUN PARAMETER | |
Input | 12~18VPP |
Voltage Frequency | Around 22KHZ |
Input Current | <0.5A |
Output Voltage | 15~100KV Negative |
Max.Output powder volume | Around 600G/MIN |
Gun cable | 4 M |
Gun weight | 425g |





Galin powder coating Equipment can be used for Hub
Galin powder coating Equipment can be used for Furnitur
Galin powder coating Equipment can be used for Metal Rail
Galin powder coating Equipment can be used for Metal products
Galin powder coating Equipment can be used for Glass products
Galin powder coating Equipment can be used for Metal or Glass Cup
Galin powder coating Equipment can be used for Any Metal or Glass you want
Galin Manual powder coating Equipment (TCL-3) can be used for Grooves and Corners
Galin Manual powder coating Equipment (TCL-3) can be used for Complex and Difficult Workpiece


- Daily Maintenance
2. Clean the powder gun
3. Clean the powder hose and suction unit
- Weekly Maintenance
2. Check the control unit grounding connections to the coating booth bolts,
the suspension devices of the work pieces,or the conveyor.
TROUBLESHOOTING GUIDE
If the powder gun does not spray powder although the control unit is switched on,then the injector can be dirty or clogged.
Error/cause | Troubleshooting |
Injector nozzle, non-return valve unit, powder hose or powder gun are clogged | Clean the corresponding parts and if necessary,replace them |
Conveying vacuum too low | Increase the powder quantity and/ or total air volume on the control unit |
Insert sleeve worn , not or incorrect inserted | Replace or insert it ,observe the indexing cam |
Insert sleeve is worm after a short operating duration | Clean the nozzle ,if damaged,replaced it |
The gun does not spray powder although the control unit is switched on and the gun trigger is pressed | 1.Connect the equipment to the compressed air 2.Clean /Replace 3.Clean the corresponding 4.Contact Galin representative |