Parameter Category | Parameter | Value/Specification |
General Parameters | Main Dimensions | 60 * 34.5 * 19 mm |
Weight | 80g (excluding peripheral accessories) | |
Operating Temperature | -40 to +85 °C | |
Operating Humidity | 45% to 95% RH | |
Contact Parameters | Contact Material | AgSnO2 |
Contact Form | 2A or 2B (2 sets of Normally Open or Normally Closed) | |
Contact Resistance | ≤ 0.8 mΩ (initial value, @DC 6~24V, 1A) | |
Maximum Switching Current | 90A | |
Maximum Switching Voltage | 250VAC | |
Performance Parameters | Rated Coil Voltage | DC 6, 9, 12, 24V |
Pulse Duration | 100ms ~ 200ms (recommended) | |
Rated Coil Power | 2.5W (single coil), 5W (dual coil) | |
Pick-up Time | ≤ 30ms | |
Release Time | ≤ 30ms | |
Electrical Life | 10,000 operations (purely resistive load, 90A 230VAC) | |
Mechanical Life | 100,000 operations | |
Insulation Resistance | 1000 MΩ (500VDC) | |
Coil to Contacts | 4000VAC, 50/60Hz, 1 min | |
Between Different Contact Groups | 4000VAC, 50/60Hz, 1 min | |
Across Open Contacts of Same Group | 2000VAC, 50/60Hz, 1 min | |
Short-Circuit Current Withstand | 4500A (50/60Hz), ~10ms (non-explosive) | |
Shock Resistance (Functional) | 100 m/s² (10G) | |
Shock Resistance (Destructive) | 1000 m/s² (100G) | |
Vibration | 1.5mm (double amplitude), 10~55Hz |





1.Suggestions of relay's input
(1)Polarity-Please check the polarity inside of our technical specification, if single coil then"+ -" or "- +"are fine,
(3)Relays'contact status may be changed during transportation or installation due to impact of external force,
therefore please reset to the required status.
(1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after