Low Voltage 3p 160A 200A 225A 250A Moulded Case Circuit Breaker MCCB
Moulded Case Circuit Breaker MCCB
Standard:
circuit breaker and auxiliaries comply with the following international standard:
1.IEC/EN 60947-1
Low-voltage switchgear and controlgear-part 1: General rules;
2.IEC/EN 60947-2
Low-voltage switchgear and controlgear-part 2: Circuit breakers;
MCCB(Standard use environment for MCCB)
1. Ambient temperature: Within the range of -5ºC--+55ºC(However, when the temperature exceed 40ºC,it should be considered to reduce the capacity to use);
2. Relative humidity: Within the range of 45%--85%;
3. Altitude: 2000m or less(However, if it exceeds 1000m, atmosphere correction through humidity test and withstand voltage test can be considered);
4. Atmosphere where excessive steam, oil steam, smoke, dust, salt and other corrosive materials do not exist;
Classification:
According to the poles: 2-poles, 3-poles
According to the rated current: Fix type
| Thermal-Magnetic fixed type Circuit Breakers | ||||||
| Model | BYM1-800 | |||||
| Breaking Capacity Code | M | H | ||||
| Rated Current of Frame size- Inm (A) | 800A | |||||
| Rated Current-In(40,50 or 55ºC) (A) | 630.700.800 | |||||
| Rated İnsulation Voltage -Ui(a.c.) 50-60Hz (V) | 800V | |||||
| Rated operation Voltage -Ue(a.c.) 50-60Hz (V) | 400/690 | 400 | 400 | |||
| Number of Pole | 3 | 4 | 3 | |||
| Rated ultimate short Circuit breaking Capacity kA Icu AC400V/50Hz O-CO (KA) | 50 | 86 | 100 | |||
| Rated service short Circuit breaking Capacity kA Ics AC400V/50Hz O-CO-CO (KA) | 20 | 30 | 65 | |||
| Rated short-circuit breaking capacity Icm(peak)/cos ф AC400V/50HZ O-CO (KA) | 73.5/0.25 | 110/0.25 | ||||
| Rated impulse withstand Voltage -Uimp (V) | 8000 | |||||
| Dielectric Propery (V) | 3000 | |||||
| lonization distance (mm) | ≤100/0 | |||||
| Endurance | Total Cycles | 8000 | ||||
| Electrical Life | 1000 | |||||
| Mechanical Life | 7000 | |||||
| Over Current trip | Thermal and Magnetic release fix type | √ | ||||
| Category (EN 14048.2/IEC 60947-2) | Main circuit | A/0 | ||||
| Auxiliary circuit | AC-15 | |||||
| Under Voltage Release | √ | |||||
| Shunt Release | √ | |||||
| Auxiliary Contact | √ | |||||
| Alarm Contact | √ | |||||
| Auxiliary Contact and Alarm Contact | √ | |||||
| Handle Operation Mechanism | √ | |||||
| Electrical Operastion Mechanism | √ | |||||
| Terminal cover | √ | |||||
| Phase seperator | √ | |||||
| Extention Handle | - | |||||
| W (mm) | 3P | 210 | ||||
| 4P | 280 | |||||
| L (mm) | 3P | 280 | ||||
| 4P | 280 | |||||
| H (mm) | 3P | 115.5 | ||||
| 4P | 115.5 | |||||
| Weight | Fixed version 3P/4P | 1.2/1.6 | ||||
| Plug-in version 3P/4P | 1.4/1.8 | |||||
| Draw out version 3P/4P | - | |||||