SUG61005TDX
1 Year
1 Year
1-50
Noise Signal Generator
1
LCD
PRIMA
Wooden Packing for Lightning Surge Simulator
10KV for lightning surge simulator
China
9030899090
Product Description
Meet EN/IEC61000-4-5 combined wave lightning surge simulator

Surge simulators/ Lightning surge generators
Product characteristic:
Fully compliant with the latest standards of IEC61000-4-5&EN61000-4-5
Touch screen display, Intelligent control, Use the Programmable imported high-voltage power supply, Reliable performance
Built-in international standards level parameters and user models parameters, simple
Built-in intelligent couping / decoupling network. Testing safety
Impulse injected the phase angle asynchronous or 0-360 ° free to set
The surge test Fully automatic switching without human operation





Surge simulators/ Lightning surge generators
Product characteristic:
Fully compliant with the latest standards of IEC61000-4-5&EN61000-4-5
Touch screen display, Intelligent control, Use the Programmable imported high-voltage power supply, Reliable performance
Built-in international standards level parameters and user models parameters, simple
Built-in intelligent couping / decoupling network. Testing safety
Impulse injected the phase angle asynchronous or 0-360 ° free to set
The surge test Fully automatic switching without human operation
| Model | SUG61005TBX (10KV) (15KV) (20KV) Optional |
| Open -circuit voltage Short-circuit current | Open -circuit t voltage 1.2/50 μ s 0.2~ 20kV Short-circuit current 8 /20 μ s ,0.1~ 10kA |
| Surge polarity | Positive / Negative/Asynchronism |
| Phase | Synchronism 0 °~ 360 °selectable/Asynchronism |
| Output impedance | Complex impedance: 2 Ω 12 Ω |
| Coupling path | Built-in, 1- phase three line,,max 16A |
| Surge count | 1~9999 |
| Surge interval | 10~999S |
| Working power supply | AC220V 50/60Hz |
| Ambient temperature | 15ºC~35ºC |
| Outline dimensions | 1480×620×620 |
| Model | SUG61005TCX (10KV) (15KV) (20KV) Optional |
| Open -circuit voltage Short-circuit current | Open -circuit t voltage 1.2/50 μ s 0.2~ 20kV Short-circuit current 8 /20 μ s ,0.1~ 10kA |
| Surge polarity | Positive / Negative/Asynchronism |
| Phase | Synchronism 0 °~ 360 °selectable/Asynchronism |
| Output impedance | Complex impedance: 2 Ω 12 Ω |
| Coupling path | Built-in, 3- phase five lines,,max 16A |
| Surge count | 1~9999 |
| Surge interval | 10~999S |
| Working power supply | AC220V 50/60Hz |
| Ambient temperature | 15ºC~35ºC |
| Outline dimensions | 1480×620×620 |
| Model | SUG61005TDX |
| Open -circuit t voltage/short-circuit current | Open -circuit t voltage: 1.2/50 μ s , 0.2~ 10kV (6KV,15KV Optional) Short-circuit current 8 /20 μ s ,0.1~5kA CCITT:Open -circuit : 10/700 μ s ,0.2 ~ 10kV (6KV,15KV Optional) Short-circuit current : 5 /320 μ s |
| Surge polarity | Positive / Negative/Asynchronism |
| Phase | Synchronism 0 °~ 360 °selectable/Asynchronism |
| Output impedance | Complex impedance: 2 Ω 12 Ω CCITT: 40 Ω,15Ω |
| CDN | Built-in, three phase five line,,max 16A |
| Surge count | 1~9999 |
| Surge interval | 10~999S |
| Working power supply | AC220V 50/60Hz |