MOX
Electrochemical Gas Sensor
Non-conductivity Type
Analog Type
Integration
Metal
High
CE
Non-Customized
13 Months From Date of Despatch
0-100% O2
Linear 0% to 100% O2 (See Note1)
9 Mv -14 Mv
< 1 % Volume O2 at Constant Temperature and Pressu
< 12 S to 90 % of Final Value
-0.03 % Rel. Per % Rh at 25 °c
0 °c - +50 °c
-20°c to +50°c
42g
CITY
Cartons
Germany
9027100090
Product Description
Product Description
 
Poisoning
CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation. When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.
Intended Use
These sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia (not including xenon), critical care, incubators and general oxygen monitors
An 'Instruction For Use' leaflet (RM945 Issue 1.0) is included with each sensor.
Stablisation Time
Allow at least 15 minutes to stabilise in the instrument before calibration or refer to manufacturer's instructions.
Cleaning and Sterilisation
In case of contamination the sensor may be cleaned with disculled water and allowed to dry naturally. The sensor is not suitable for sterilisation by steam or exposure to chemicals such as ethylene oxide or hydrogen peroxide.
Calibration Interval
These sensors are designed to have minimal drift over their useful lifetime. For maximum accuracy however, they should be calibrated before each use.
If the Sensor is Dropped
If a sensor is dropped, then it should be placed in quarantine for 24 hours and a follow-up check made by a 2 point calibration.
Mechanical Installation
When installing the sensor, it must only be screwed in hand-tight and a gas tight seal ensured. Spanners and similar mechanical aids may not be used, as excessive force may damage the sensor thread.




 
 
 
 
Company Information

Packaging & Shipping

 

FAQ

  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$2068.66 1 pieces(MOQ)

Honeywell Xnx Gas Detector Universal Transmitter Xnx-Rmse-Nhnnn Co CO2 H2 H2s Cl2

Ningxia Maiya Sensor Technology Development Co., Ltd
$24.60 1 pieces(MOQ)

Original UK City 4oxv O2 Gas Detector Alarm Sensor Oxygen Gas Analyzer

Ningxia Maiya Sensor Technology Development Co., Ltd
$219.25 1 pieces(MOQ)

Bw Solo Wireless H2s Single Gas Detector Honeywell Handheld H2s Gas Alarm Portable Gas Leake Detector

Ningxia Maiya Sensor Technology Development Co., Ltd
$149.25 1 Piece(MOQ)

Quick Fuel Cell Tester LCD Screen Rapid Alcohol Breathalyzer

Ningxia Maiya Sensor Technology Development Co., Ltd
$68.70 1 Piece(MOQ)

4CS2-M Styrene Gas Electrochemical Sensor

HUBEI AERITECH CO., LTD.
$68.70 1 Piece(MOQ)

4pH3-L Phosphine Gas Electrochemical Sensor

HUBEI AERITECH CO., LTD.
$47.00 1 pieces(MOQ)

for Various Ventilators and Oxygen Concentrators Oxygen Sensor O2 Sensor

Ningxia Maiya Sensor Technology Development Co., Ltd
$300.00 1 pieces(MOQ)

Infrared Combustible Gas Sensor for Accurate Measurement

Taizhou Jiabo Intrument Technology Co., Ltd.
$68.70 1 Piece(MOQ)

4PA-100 Propargyl Alcohol Gas Electrochemical Sensor

HUBEI AERITECH CO., LTD.
$7.50 100 Pieces(MOQ)

Modernized Design High Stability Alarm Gas Detector

Shenzhen Taian Electronics Co., Ltd.