AC Side Parameters | |
Rated grid voltage | 400Vac(380/400/415Vac can be set) |
Grid voltage range | 304Vac-485Vac |
Grid voltage frequency | 50/60±5% (50Hz/60Hz two modes adaptive) |
Voltage system | Three-phase four-wire (3W+PE) |
Input current | ≤29A |
Power factor | ≥0.99,Fully loaded |
Current harmonics | <3%,Fully loaded |
Battery Side Parameters | |
output voltage | 100-300VDC,rated 150VDC |
Output rated current | 100A |
Rated power | 15KW |
Charging efficiency | 95max(Use SIC devices), 94%(Use Si devices) |
Voltage stabilized accuracy | ±0.5% |
Current stabilized accuracy | ±1% |
Ripple factor | <1%Vo |
Discharge Part
Battery Side Parameters | |
Battery voltage range | 100-300VDC |
Discharge current | 100A Max |
AC Side Parameters/V2G(on-grid discharge) | |
Grid voltage range | 304Vac-485Vac |
Grid voltage frequency | 50/60±5%(50Hz/60Hz two modes adaptive) |
Rated power | 15KW |
Effectiveness | 95%max(Use SIC devices),94%(Use Si devices) |