| SPECIFICATIONS | ||||
| OUTPUT | ||||
| MODEL | PS-45-5 | PS-45-12 | PS-45-15 | PS-45-24 |
| DC Voltage | 5V | 12V | 15V | 24V |
| Rated Current | 8.0A | 3.7A | 3.0A | 1.9A |
| Rated Power | 40W | 44.4W | 45W | 45.6W |
| Ripple & Noise | 100mV | 100mV | 100mV | 150mV |
| Voltage Tolerance | ±3% | ±2% | ±2% | ±2% |
| Line regulation | ±1% | ±1% | ±1% | ±1% |
| Load regulation | ±3% | ±2% | ±2% | ±2% |
| Setup, Rise, Hold Up Time | 800ms,30ms,60ms at full load | |||
| Voltage Range | 90-264VAC 47-440Hz; 127-370VDC | |||
| Efficiency | 74% | 76% | 77% | 78% |
| Inrush Current | Cold-start current 15A/115V 30A/230VAC | |||
| Leakage current | <0.75mA/240VAC | |||
| Over Load | 53-75W rated output power | |||
| Protection type: hiccup mode, recovery automatically after fault condition is removed | ||||
| Working Temp., Humidity | -10ºC~+60ºC(Refer to output derating curve),20%~90%RH non-condensing | |||
| Storage Temp., Humidity | -20ºC~+85ºC, 10%~95%RH | |||
| Vibration | 10~500Hz,2G 10min,/1cycle,Period for 60min,Each along X, Y, Z axes | |||
| Withstand Voltage | I/P-O/P: 3KVAC I/P-FG: 2KVAC O/P-FG: 0.5KVAC | |||
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25ºC/70% RH | |||
| Safety Standard | Meet UL60950-1.TUV EN60950-1 approved | |||
| EMC Standard | EN5022 CLASS B EN61000-3-2-3, EN61000-4-2,3,4,5,6,8,11,EN55024, light industry level, criteria A | |||
| Dimension | 127*76.2*28mm(L*W*H) | |||
| Weight | 0.19Kg | |||
| Packing | 72PCS/15.6Kg/1.35CUFT | |||