fixed ultrasonic portable ultrasonic flowmeter(clamp on)
flow meter,Ultrasonic flow meter
1.Accuracy:Better than 1%
2.Repeatability:0.2%
3.Keypad:4x4-key
4.Velocity:0.03-32 m/s
1. Built-in printer
2. Built-in data logger

Ultrasonic flow meter is designed to measure the velocity of liquid within a closed conduit. It uses the well-known transit-time measurement principle, plus our proprietary signal processing and ultrasonic transceiving technologies.
Portable ultrasonic flow meter
Handheld ultrasonic flow meter
Separate fixed ultrasonic flow meter
Applicable medium: Water, sea water, fuel oil and other single, uniform and stable liquid which can conduct ultrasonic
Features:
l High Accuracy measuring
Linearity: better than 0.5%, Repeatability: better than 0.2%, Accuracy: better than ±1%
l Non-intrusive measuring
Non-intrusive, clamp-on transducer, no pressure drop, no pipe disturbance.
l Wide measuring range
Several types transducer for selection, measuring pipe size from DN15mm to DN6000mm
l Chinese & English menu
Chinese & English display, easy to operate.
l Built-in printer
Built-in mini thermal printer with instant and timing print function
l Built-in data logger
Uplink over 20 measuring data to computer or SD card, convenient for the data processing and applications
l Multi-signal input &output
l Multiple signal interface easy for input and output signals



TUF-2000 Series fixed ultrasonic flowmeter is widely used in various industrial field-line flow measurement of liquid.
Typical Applications
The TUF-2000P ultrasonic flow meter can be virtually applied to a wide range of measurements. The measured pipe ranges 15-6000mm. Because the instrument and transducers are non-contacting and have no moving parts; The flow meter can not be affected by system pressure, fouling or wear. Standard transducers are rated to 110 º C. For further information, please consult the manufacturer for assistance.
Sensor:
1.External clamp-on sensor (fluid temperature: ≤ 110 Degrees Celsius)
Standard small sensor S1 type (magnetic)
For diameter: DN15-100mm Dimension: 45 × 30 × 30mm
Quality: 75 grams
2.External clamp-on sensor (fluid temperature: ≤ 110 Degrees Celsius)
Standard M1-type medium-sized sensors (magnetic)
For diameter: DN50-700mm
Dimensions: 60 × 45 × 45mm
Quality: 250 g
3.External clamp-on sensor (fluid temperature: ≤ 110 Degrees Celsius)
Standard large-scale sensor type L1
For diameter: DN300-6000mm
Dimensions: 80 × 70 × 55mm
Quality: 528 g

| Items | Specifications |
| Main unit | 2 line x 20 character LCD with backlight |
| Working temperature: -25--60°C | |
| Mini thermal printer with 24 line character output | |
| 4x4+2 pushbutton keypad | |
| RS-485 interface for networking | |
| Signal input & output | 1 channel 4-20mA output |
| 1channel OCT output | |
| 1channel relay output | |
| 3 channel 4-20mA input | |
| Medium | Water (hot water, chilled water, city water, sea water, waste water, etc.); Sewage with small particle content; |
| Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.); Chemicals (alcohol, acids, etc.); Plant effluent; Beverage, | |
| liquid food; Ultra-pure liquids; Solvents and other liquids | |
| Flow rate | 0~±30m/s |
| Accuracy | Better than ±1% |
| Battery | Built-in rechargeable Ni-MH rechargeable battery, provide over 20 hours of continuous operation |
| Power Consumption | 1.5W |
| Power supply | Built-in rechargeable Ni-MH battery (for 20 hours operation) or AC 220V |
| Weight & Dimensions | 2.5kg ; 225*180*67mm: |
| Remarks | With a high strength carrying case suitable for normal and harsh environment |













Audited Supplier