* True RMS measurements (512 samples/cycle)
* For single-phase, two-phase, three-phase system
* Measurements:VL-L, VL-N, I, In, Cos , Pf, Hz, W, ∑W, Va, ∑Va, Var, ∑Var, import Kwh, export Kwh import Kvarh,
  export Kvarh, V-THD, I-THD,1-63th harmonic , system running hours, % voltage unbalance, % current unbalance,
  % system load, total frequency
* 3 voltage and 4 current input (Measure or calculate the neutral current)
* Voltage Input: 0-690Vac, Current input: 1 or 5A CT selective
* % system load and system running hours
* Detects CT wiring errors
* Maximum, minimum and demand for U, I, P, Q, S in hours, days, months
* Real time clock with integrated backup rechargeable battery
* 4 quadrants energy measurement and monthly energy calculation
* 2 pulse output and RS485 communication: Modbus RTU
* Waveforms capture and phase diagram for voltage, current
* Built in 1Mbit memory
* Alarm event log
* English, Chinese (traditional & simplied)
* Moduel function options (only one can be selected)
   - 7 digital input +2 relay output(remote or alarm)(Standard)
   - 7 digital input +2 analog output(4-20mA) for V1,V2,V3,V12,V23,V31,I1,I2,I3 (option)
   - Ethernet (Modbus TCP), Web server+2 digital input +2 relay output(remote or alarm) (option)
   - LoRa wireless (Private protocol)+2 digital input+2 relay output (remote or alarm)(option)
   - RS-485 interface (Modbus RTU)+2 digital input+2 relay output (remote or alarm)(option)
   - WIFI wireless +2 digital input +2 relay output(remote or alarm) (option)
| Auxiliary Supply | |
| Operating voltage (Un) | 85···265 VAC 50/60Hz 10W / 100-285VDC/24-48VDC(depend on order) | 
| Power consumption | 4VA max | 
| Measurement input | |
| Voltage inputs for direct connection: | Phase-neutral(L-N): max 400V RMS CAT III | 
| Input impedance(for direct voltage inputs): | >4MΩ | 
| CT inputs: | max 5.5A RMS | 
| CT inputs overload capacity: | max 10A | 
| CT inputs Self-consumption : | < 0.2VA | 
| Accuracy | |
| Three phase voltage: | ± 0.2% | 
| Currents: | ± 0.2% | 
| Powers: | ± 0.5% | 
| Powers factor: | ± 0.5% | 
| Frequency: | ± 0.02% | 
| Harmonics: | ± 1% | 
| Active energy: | Class 0.5S | 
| Reactive energy: | Class 0.5S | 
| Insulation | |
Insulation voltage  | 3kV for 1 min., 50Hz   | 
| Display | |
Display type   | 3.2inch 240x160 pix LCD | 
| I/O | |
Digital inputs:   | Active dry contact  | 
Digital outputs:   | 2 Relay N/O 220VAC 5A  | 
Analog outputs:  | 4-20mADC / max load 500Ω   | 
Pulse output:   | 24-30VDC Max.50mA, Min. 50msec pulse width  | 
| Memory | |
Recording memory:   | Built in 1Mbit memory | 
| Communication | |
Ethernet port:   | Auto MDIX Rj45 10/100 Base Ethernet   | 
RS-485 port:   | 1 optoisolated, 4800-57600   | 
Protocols:   | HTTP, HTTPS, Modbus RTU/TCP  | 
| Environmental conditions | |
Opterating temperature:   | -10···+55°C   | 
Storage temperature:   | -25···+75°C  | 
Relative humidity:   | 95% max without condensing  | 
Altitude:   | max 2000m AMSL   | 
Installation & use:   | Internal   | 
| Mechanical characteristics | |
Mounting:   | Panel mount 96x96mm(The panel cut-size 92*92mm)  | 
Size:   | Front(WXH)96x96mm, Rear (HxD) 90x70mm   | 
Degree of protection:  | IP40(optional IP54) on front, IP20 housing and terminals   | 
Weight:   | 400g  | 
| Standard compliance | |
| reference standard: | IEC61010-1; IEC61557-1;IEC61557-12; IEC61326-1;IEC62053-21;  IEC62053-22; IEC62053-31; IEC60068-2-1; IEC60068-2-30;  IEC60364-5-52; IEC61000-3-2; IEC61000-3-3; IEC61000-4-2;  IEC61000-4-3; IEC61000-4-4; IEC61000-4-5; IEC61000-4-6;  IEC61000-4-8; IEC61000-4-11; IEC61000-4-30  | 












  