RYZER® portfolios are designed for operation in any industrial environment taking into account every aspect for long-term economic viability. The entire system is designed for typical industrial lifetimes (as standard: 20 years for mechanical components), 24/7 operation, serviceability and remote monitoring.
RYZER® cabinet system named as Ryzer-XX-CAB, for example, Ryzer-5CMH-1.6-CAB means the key parmeter of H2 production is 5Nm3/h and H2 outlet pressure reached 1.6MPa.Ryzer cabinet system is a Smart integration system and maintenance free, the overall PEM stack, control and full BOP install into one cabinet.
Product Name | Ryzer-5CMH-1.6-CAB (means 10Nm3/h @1.6MPa) |
Arrangement | Cabinet System |
H2 Production | 5 Nm3H2/h (Customized) |
DC Power Consumption of stack | ≤4.1 kWh/Nm3H2 |
AC Power Consumption of system | ≤ 4.5 kWh/Nm3H2 |
Working Temp. | 65±5 ºC |
Ambient Temp. | 5~40 ºC |
Hydrogen Purity (after Purification) | 99.999% |
Outlet H2 pressure | ≤ 1.6 MPa (customized) |
Cold/Warm Start time | ≤10 min / 3 s |
Load Regulation Range | 10 % ~ 100 % |
Design Life (stack / system) | ≥ 80,000 h |
Water quality | ≥10 MΩcm(1.1m3/h pure water capacity) |
Size* | 1550x1300x2200* |
weight | <1000 kg |
Technical remarks | Standard BB design, Smart integration system |
The PEM stack of H-RAY is able to operate more than 80,000 hours or 10 years. whichever comes first, based on continuous full-load operation. Depending on the business case and the commercial calculations the stacks can be replaced at any time. The process part as well as the entire PEM electrolysis system (System and BOP) is designed for typical industrial lifetimes > 25 years.


Advantage:
1. In-house developed Zero-pole pitch, high-activity PEM catalytic electrode
2. Excellent mass and heat transfer chemical process performance of bipolar multi-element electrolytic cell structure
3. No chemicals are added, corrosion resistance, passivation resistance and other superior performance of bipolar multi-element electrolytic cell material selection
4. Real-time monitoring System ensuring uninterrupted operation, such as water shortage, overpressure, waterproof, explosion-proof ,smart automatic protection system ensuring higher safety
5. Electrolysis of pure water (eliminating alkali addition) for hydrogen production, no corrosion, no pollution, high hydrogen purity
6. Lower voltage and higher current density operation, low internal resistance of electrolyzer without heating, long-life operation and replacement free, higher hydrogen purity.
7. Sufficient H2 production based on short startup time and fast pressure boost (3-5 minutes)
8. Stabilization pressure and steady flow output of Hydrogen, automatic monitoring and tracking system to the change of power consumption.
9. Real-time monitoring System ensuring uninterrupted operation, such as water shortage, overpressure, waterproof, explosion-proof ,smart automatic protection system ensuring higher safety
10. Lower noise
11.Lower power consumption, high electrolysis efficiency
12. Smart integration system with full BOP in one cabinet. "plug and play" concept reduce site activity and time.


