| SPECIFICATION | ||
| Model | SC-120-12 | SC-120-24 |
| DC Voltage | 13.8V | 27.6V |
| Rated Current | 8A | 4A |
| Current Range | 0-8A | 0-4A |
| Rated Power | 117.1W | 118.4W |
| Ripple & Noise | 120mVp-p | 180mVp-p |
| Voltage Adj. Range | +15,-5% | +15,-5% |
| Voltage Tolerance | ±2% | ±1% |
| Inlet Stability | ±1% | ±1% |
| Load Stability | ±2% | ±1% |
| Setup, Rise, Hold Up Time | 500ms,30ms/230VAC 1200ms,30ms/115VAC at full load | |
| Voltage Range | 90-132VAC/180-264VAC Selected by switching | |
| Frequency Range | 47-63Hz | |
| AC Current | 2.8A/115V 1.4A/230VAC | |
| Efficiency | 81% | 83% |
| Inrush Current | Cold-start 30A | |
| Leakage Current | <2mA/240VAC | |
| Over Load | 8.8A~12A rated output power | 4.4A~6A rated output power |
| Protection type: hiccup mode,recovers automatically after fault condition is removed | ||
| Over Voltage | 16.6~19.3V | 33.1~38.5V |
| Protection type: shut down o/p voltage, re-power on to recover | ||
| Working Temp., Humidity | -20ºC~+60ºC(Refer to output derating curve),20%~90%RH | |
| Storage Temp., Humidity | -40ºC~+85ºC, 10%~95%RH | |
| Temp. Coefficient | ±0.05%/ºC(0~45ºC) | |
| Vibration | 10~500Hz,2G 10min,/1cycle,Period for 60min,Each along X.Y.Z axes | |
| Safety Standard | UL60950-1,CCC,CE | |
| EMC Standard | Design refer to EN55022(CLSPR22),EN61000-3-2,-3, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024 | |
| OTHERS | ||
| Dimension | 159*97*38mm(L*W*H) | |
| Weight | 0.56Kg/pc 45pcs/carton | |