2. When thermocouple tips is heated by fire, cold and heat generate thermoelectric power due to temperature difference, to form closed loop current and make magneticvalve actuation,opening gas path.
3. When the flame is out owing to unexpected reasons, thermocouple rapidly lose potential, magnet valve lose suction under the action of spring, so close gas path, and play a safety protection role.
Product Name | Sinopts furnace gas valve replacement gas parts |
Applicable gas species | Natgas, LPG, artificial coal gas etc |
Opening electrical current | ≤120mA |
Closing electrical current | ≥40mA |
Free stroke | 49.5±0.5mm |
Working stroke | 42.5±0.4mm |
Inherent resistance | 20mΩ±10% |
Sealing force(full compression) | ≥4.8N |













Audited Supplier