√ Adopting high-frequency design, high power density, small size, and high overall efficiency;
√ Bidirectional energy storage design enables bidirectional flow control of energy, and both photovoltaic and mains power can charge the battery;
√ Ultra wide MPPT range,with a minimum of 40Vdc (24V model)/80Vdc (48V model);
√Capable of setting working modes (grid connected mode, off grid mode, hybrid mode);
√ Equipped with grid connected current setting function;
√ Equipped with output priority setting function;
√ Equipped with charging priority setting function;












| Product model: HF | 33224 | 43224 | 63248 | 83248 | 103248 | 123248 | |
Photovoltaic | Maximum photovoltaic input power | 5000W | 7000W | 4500W*2 | 6000W*2 | 6000W*2 | |
| MPPT tracking voltage range | 40VDC -450VDC | 80VDC-450VDC | |||||
| Rated input voltage | 360VDC | ||||||
| Maximum photovoltaic input voltage Voc (Under the lowest temperature conditions) | 500VDC | ||||||
| Maximum photovoltaic input current | 18A | 27A | 18A*2 | 22A*2 | 27A*2 | ||
| MPPT tracking channels (input channels) | 1 | 2 | |||||
Battery&Charging | Battery type | Valve hole lead-acid battery/lithium battery | |||||
| Custom battery (can set charging and discharging parameters for different types of batteries through the operation panel) | |||||||
| Rated battery voltage | 24VDC | 48VDC | |||||
| Battery voltage range | 21~30VDC(default value) | 42~60VDC(default value) | |||||
| Maximum photovoltaic charging current | 120A | 150A | 120A | 150A | 180A | 200A | |
| Maximum mains charging current | 80A | 100A | 80A | 100A | 120A | 140A | |
| Maximum charging current | 120A | 150A | 120A | 150A | 180A | 200A | |
| On-grid Operation | |||||||
On-grid (AC ) | Rated output power | 3300W | 4300W | 6300W | 8300W | 10.3KW | 12.3KW |
| Rated output voltage | 220VAC/230VAC/240VAC | ||||||
| Output voltage range | 187VAC~264VAC | ||||||
| Rated output frequency | 50Hz/60Hz | ||||||
| frequency range | 47Hz~52Hz(50Hz),57Hz~62Hz(60Hz) | ||||||
| Rated output current | 14.5A/13.9A/13.3A | 19.5A/18.7A/17.9A | 28.6A/27.4A/26.2A | 37.7A/36.1A/34.6A | 46.7A/44.9A/42.9A | 55.9A/53.5A/51.3A | |
| power factor | >0.98(Rated power) | ||||||
| Off-grid operation | |||||||
| AC Input | Rated input voltage | 220V /230V/240V | |||||
| Range of mains input voltage | 165VAC -280VAC/ 120VAC~280VAC(Can be set) | ||||||
| Rated input frequency | 50Hz/60Hz | ||||||
| Input frequency range | 45Hz~55Hz(50Hz) ,55Hz~65Hz(60Hz) | ||||||
AC output | Rated output power | 3300W | 4300W | 6300W | 8300W | 10.3KW | 12.3KW |
| Rated output voltage | 220V /230V/240V | ||||||
| Output voltage accuracy | ±2% | ||||||
| Rated output frequency | 50Hz/60Hz | ||||||
| Output frequency accuracy | ±1% | ||||||
| Output waveform | Pure sine wave | ||||||
| Hybrid operation (complementary mode)) | |||||||
| AC Input | Rated input voltage | 220V /230V/240V | |||||
| Range of mains input voltage | 187VAC~264VAC | ||||||
| Rated input frequency | 50Hz/60Hz | ||||||
| Input frequency range | 47Hz~52Hz(50Hz) ,57Hz-62Hz(60Hz) | ||||||
| AC output | Rated output power | 3300W | 4300W | 6300W | 8300W | 10.3KW | 12.3KW |
| Rated voltage | 220VAC/230VAC/240VAC | ||||||
| Rated output current | 14.5A/13.9A/13.3A | 19.5A/18.7A/17.9A | 28.6A/27.4A/26.2A | 37.7A/36.1A/34.6A | 46.7A/44.9A/42.9A | 55.9A/53.5A/51.3A | |
| General parameters | |||||||
| Maximum conversion efficiency (battery discharge) | 94%(Peak value) | ||||||
| MPPT tracking efficiency | ≥99.9 | ||||||
| Conversion time | 10ms(Typical value) | ||||||
| Panel display | LCD+LED | ||||||
| Heat dissipation method | Intelligent fan control | ||||||
| Communication capability | RS485/Mobile APP (WIFI monitoring or GPRS monitoring) (optional) | ||||||
| Protection level | IP20 | ||||||
| Installation method | Wall mounted | ||||||
Protection | Battery undervoltage alarm | 22VDC(default value) | 44VDC(default value) | ||||
| Battery undervoltage protection | 21VDC(default value) | 42VDC(default value) | |||||
| Anti islanding protection | ≤2S | ||||||
| Overload power protection | Automatic protection (battery mode), circuit breaker or fuse (mains mode) | ||||||
| Output short circuit protection | Automatic protection (battery mode), circuit breaker or fuse (mains mode) | ||||||
| Over temperature protection | > 90 ºC(Turn off inverter and charging) | ||||||
Environment | working temperature | -10ºC ~50ºC | |||||
| Storage temperature | -15ºC ~60ºC | ||||||
| noise | ≤55dB | ||||||
| Altitude | 2000m(Exceeding the usage limit requires a reduction in usage) | ||||||
| relative humidity | 0%~95% ,No condensation | ||||||
| Size and weight | |||||||
| Product size(L*W*Hmm) | 325*275*102 | 375*297*102 | 390*320*112 | 515*365*117 | 535*462*117 | 630*540*130 | |
| Packaging size(L*W*Hmm) | 400*330*167 | 450*352*167 | 465*375*187 | 615*460*212 | 630*557*212 | 730*635*225 | |
| Net weight(kg) | 5.5 | 6.7 | 8 | 13 | 14.7 | 22 | |
| Gross weight(kg) | 6.5 | 8 | 9.5 | 15 | 17 | 25 | |












Audited Supplier