Tunkia Co., Ltd.

VIP   Audited Supplier 4 years
Profile Certified by SGS/BV
TH3600
24 Hours
1 year
Electromagnetic Instrument, Electrical Calibrator
Electricity
With LCD Display
Non-Customized
0.005 (50 ppm) / 0.01(100 ppm)
528 V
120 mA
20μA
2nd to 63rd
AC ( 220 ± 22 ) V, ( 50 ± 2 ) Hz
RS232, LAN
TUNKIA
Package for Exporting
China
Product Description
 
TH3600 Broadband Low Current Standard Power Source
 
1.Summary

TH3600 is a three-phase standard power source with wide frequency and low current output. The output bandwidth is 45 Hz~1kHz, and the low current output can be as low as 20μA. It can be used as a power/energy calibration source for high-precision current measurement and analysis below 120mA. It makes up for the serious shortcomings of traditional electric energy meter calibration devices in broadband and low current measurement. It has optional power accuracy of class 0.005 and 0.01.

2.Features
  1. Maximum output: 528 V / 120 mA, which can ensure the stability of value output under full load conditions.
  2. Minimum current output: as low as 20μA.
  3. Multi-functional electric energy measurement: It has forward, reverse active and reactive energy, and supports the calibration of electric energy meters.
  4. Harmonic function (optional): Can load 2nd to 63rd harmonics with adjustable amplitude and phase to complete the harmonic impact test.
3. Specification

3.1 ACV Output

RangeResolutionLoad CapacityShort-term Stability 
( ppm / min )
Measurement Uncertainty
 ( ppm*RD+ppm*RG,45Hz~65Hz)
Total Harmonic Distortion
(THD, % )
Class 0.005Class 0.01Class 0.005Class 0.01
60 V0.01 mV0.3A51012 + 825 + 15< 0.01
120 V0.1 mV0.15A51012 + 825 + 15< 0.01
240 V0.1 mV0.08A51012 + 825 + 15< 0.01
480 V0.1 mV0.04A51012 + 825 + 15< 0.01
  1. Output range: 6 V ~ 528 V, 7-digit display
  2. Adjustment fineness: 3ppm
  3. Protection functions: short circuit protection, overload protection, temperature protection
 

3.2 ACI Output

RangeResolutionLoad CapacityShort-term Stability
( ppm / min )
Measurement Uncertainty 
 ( ppm*RD+ppm*RG,45Hz~65Hz)
Total Harmonic Distortion
(THD, % )
Class 0.005Class 0.01Class 0.005Class 0.01
0.2 mA0.1 nA8V122030 + 2050 + 30< 0.02
0.5 mA0.1 nA8V122030 + 2050 + 30< 0.02
1 mA1 nA8V81520 + 1030 + 20< 0.02
2 mA1 nA8V81520 + 1030 + 20< 0.01
5 mA1 nA8V81520 + 1030 + 20< 0.01
10 mA10 nA8V81520 + 1030 + 20< 0.01
20 mA10 nA8V81520 + 1030 + 20< 0.01
50 mA10 nA8V81520 + 1030 + 20< 0.01
100 mA100 nA8V81520 + 1030 + 20< 0.01
  1. Output range: 0.02 mA~120 mA, 7-digit display
  2. Adjustment fineness: 3ppm
  3. Protection functions: open circuit protection, overload protection, temperature protection
 

3.3 Frequency / Phase

ParameterAdjustment RangeOptimal Measurement Uncertainty (k=2)
Frequency45.0000 Hz~1000.000 Hz50 ppm*RD
Phase0.000 0°~359.999 9°0.001°
Harmonic (optional)2nd~63rd, amplitude 0~40% (total harmonic distortion does not exceed 50%), phase adjustable from 0.0°~ 359.99°
 

3.4 Power / Energy

Measured PowerVoltage RangeCurrent RangeMeasurement Uncertainty
(45Hz~65Hz,k=2)
Class 0.005Class 0.01
Active Power / Energy
Apparent Power
|cosj| ≥ 0.5
30 V ≤ U ≤ 480 V0.05 mA ≤ I <1 m A0.005%*FS0.01%*FS
1 mA ≤ I < 100 mA0.005%*RD0.01%*RD
Reactive Power
|sinj| ≥ 0.5
30 V ≤ U ≤ 480 V0.05 mA ≤ I <1 m A0.01%*FS0.02%*FS
1 mA ≤ I < 100 mA0.01%*RD0.02%*RD
Power Factor30 V ≤ U ≤ 480 V0.05 mA ≤ I <1 m A0.01%0.02%
1 mA ≤ I < 100 mA0.005%0.01%
Note: FS = voltage range value × current range value
  1. Power/electric energy measurement range: combination of AC voltage range and AC current range
  2. Power factor measurement range: -1.000 00…0.000 00…1.000 00
  3. Standard electric energy pulse output: high frequency full scale value corresponds to 60 kHz, low frequency full scale value corresponds to 6 Hz
  4. Standard power pulse input: frequency ≤ 200 kHz, voltage: 0…3.3 V…24 V
  5. Power error display: automatic, resolution 0.0001%
 
4.General Specification
Power SupplyAC ( 220 ± 22 ) V, ( 50 ± 2 ) Hz
Preheat Time30mins
Temperature PerformanceWorking temperature: 15°C~30°C;
Storage temperature: -10°C~55°C
Humidity PerformanceWorking humidity: < 80% @ 30°C, < 70% @ 40°C, < 40% @ 50°C
Storage humidity: (20%~80%) R·H, non-condensing
Communication InterfaceRS232,LAN
 

5. Ordering Information




 
Company Profile
 

  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$16000.00 1 Set(MOQ)

TD4550 Portable Three-Phase electric meter calibration Energy Meter Calibrator

Tunkia Co., Ltd.
$3650.00 1 Piece(MOQ)

Handheld digital LCD static electricity leakage Surface Resistance meter Tester Surface Insulation Resistance meter (SIR Testing)

Tunkia Co., Ltd.
$10000.00 1 Set(MOQ)

Portable Three Phase Standard Energy Meter Testing Equipment for Munltifuction Electric Meter

Tunkia Co., Ltd.
$408340.00 1 Set(MOQ)

TH3900 DC Power & Energy Reference Standard

Tunkia Co., Ltd.
$810.00 1 Set(MOQ)

COMBINED DUAL FUNCTION SMOKE HEAT DETECTOR TESTER

Universky (Jiangsu) Technologies Co., Ltd.
Negotiable 1 Set(MOQ)

Electronic Test and Measurement Instrument, Portable Energy Meter Testing Set

Tunkia Co., Ltd.
$5000.00 1 Piece(MOQ)

Test-901 1000AMP Mumbai Primary Current Injection Test Kit for Cables

Beijing GFUVE Electronics Co., Ltd.
$6538.00 1 Set(MOQ)

Test-902 Secondary Current Injection Protection Relay Tester Primary Current Injection Test Set

Beijing GFUVE Electronics Co., Ltd.
$6300.00 1 Set(MOQ)

TD1855 Multifunction Calibrator with AC/DC Power Output

Tunkia Co., Ltd.
$999.00 1 Piece(MOQ)

TD1600 AC Source for AC Current Meter Voltage Meter Calibration

Tunkia Co., Ltd.