* Product feature
Advanced heat exchange geometric structure and improved processing technology;To further reduce the heat exchange tube insideand outside thermal resistance and improve performance.The optimization of the heat exchange ; Meeting the demand of high space,long-range modern logistics refrigerator.
A variety of material of heat exchange tubes and defrosting way;Meeting the demand of more widely used and lowest cost.
Freon,saline secondary refrigerant
* Structure characteristics
1.Different material of heat exchange tubes( $ 16),Antirust aluminum ,pure copper and efficient internal thread copper pipe.
2.Different processing technology can meet the demand of different tube ,ensure the heat exchange efficiency.
3.Continuous stamping of high toughness and whole corrugated antirust and hydrophilic membrane aluminum fin can improve the heat transfer coefficient and reliability.
4.To meet the requirements of higher corrosion situation,we can also provide the heat exchange core which has overall nano coating protection.
5.All the products must carry out 2.4MPa air strength test , 0.5MPa nitrogen pressure maintaining before delivery.
* Accessories of axial fan
Protection grade lP54,insulation grade F; the working condition: --40 ~+40(C).
* Defrosting
Defrosting :electrical heating, water spray and hot gas defrosting.
Room temperature inside below -15 ºC, water pan has heat preservation processing, water outlet with electric heating device.Air guider is required for Cryogenic condition.
* Liquid supply way




Model | D45-145E/412F-T |
Evaporation area m² | 143 |
Refrigerating capacity(kW) DT1=8Kevaporating temp. -8ºC | 25.9 |
Refrigerating capacity(kW) DT1=7K evaporating temp. -25ºC | 22.6 |
Tube volume (L) | 59.14 |
Fan model (Voltage 400V,50Hz) Blade diameter(mm) | 450 |
Fan model (Voltage 400V,50Hz) Power (kw) | 0.54*4 |
Fan model (Voltage 400V,50Hz) Air flow (m³/h) | 5800*4 |
Fan model (Voltage 400V,50Hz) Quantity | 4 |
Fan model (Voltage 400V,50Hz) Noise (dB) | 75 |
Electric defrosting(Voltage 220V) Cooling coil (kW) | 2.9*6 |
Electric defrosting(Voltage 220V) Defrosting tray (kW) | 2.9*2 |
Electric defrosting(Voltage 220V) Power(kw) | 23.2 |
Liquid in(mm) φ | 11/8 |
Vapor back(mm) φ | 21/8 |
Water outfall(DN) | 40 |
Weightabout(kg) | 402 |
Outer dimension(mm) L | 4020 |
Outer dimension(mm) W | 670 |
Outer dimension(mm) H | 700 |
Outer dimension(mm) E | 1740*2 |
Outer dimension(mm) A | 695 |
Outer dimension(mm) H1 | 100 |
Outer dimension(mm) H2 | 575 |
Total thickness of frost correction parameter list,please see attachment:
Thickness of frost (mm) | Correction factor ( α) |
0 | 1 |
1 | 0.93 |
2 | 0.72 |
3 | 0.61 |
Model | Refrigerating capacity(kW) | Evaporation area m² | Tube volume (L) | Fan model (Voltage 400V,50Hz) | Water Outfall (DN) | |||
DT1=8K evaporating temp. -8ºC | DT1=7K evaporating temp. -25ºC | Blade diameter (mm) | Power (kw) | Air flow (m³/h) | ||||
D45-50E/14F-T | 6.7 | 5.2 | 49.4 | 7.39 | 450 | 0.54 | 5800 | 40 |
D45-100E/24F-T | 13.8 | 10.6 | 101.2 | 14.78 | 450 | 0.54*2 | 5800*2 | 40 |
D45-150E/34F-T | 20.1 | 15.5 | 147.9 | 22.09 | 450 | 0.54*3 | 5800*3 | 40 |
D45-200E/44F-T | 26.9 | 20.8 | 197.8 | 29.57 | 450 | 0.54*4 | 5800*4 | 40 |
D50-65E/14F-T | 8.7 | 6.7 | 63.9 | 9.53 | 500 | 0.83 | 7400 | 40 |
D50-130E/24F-T | 17.7 | 13.7 | 130.1 | 19.05 | 500 | 0.83*2 | 7400*2 | 40 |
D50-190E/34F-T | 25.9 | 20 | 190.5 | 28.48 | 500 | 0.83*3 | 7400*3 | 40 |
D50-255E/44F-T | 34.7 | 26.8 | 254.7 | 38.11 | 500 | 0.83*4 | 7400*4 | 40*2 |
D71-435E/37F-T | 68 | 54.3 | 435.6 | 43.71 | 710 | 1.75*3 | 14000*3 | 40*2 |