Y09-310 (AC-DC) Battery Operated Laser Particle Counter

Price $4000.00 Compare
Min Order 1 Piece
Availability In Stock
Shipping From Zhejiang, China
Popularity 511 people viewed
Quantity
+-
 

Zhejiang FUXIA Medical Technology Co., Ltd.

VIP   Audited Supplier 12 years
Profile Certified by SGS/BV
Y09-310 (AC-DC)
High Precision
CE, ISO
220V
Computerized
Customized
New
1 Year
Dust Laser Particle Counter
Dust Laser Particle Counter
1 Year
300*360*126 mm3; (Wide*Deep*High)
Laser Diode (30, 000 Hours Mean Time Between Failu
7.5kg
48W
<10min
28.3L/Min (Imported Pump)
Built-in Thermal Printer
10, 100, 1000, 10000, 100000, 300000class /ISO
1000 Samples (with PC Software)
86kpa-106kpa
0.3, 0.5, 1, 3, 5, 10 μm
SUGOLD
Cardboard Packaging
300*360*126 mm
Zhejiang, China
9029109000
Product Description
Y09-310 (AC-DC) Battery Operated Laser Particle Counter

Specifications:
1.28.3L/min sample flow 
2.AC-DC 
3.automatic UCL calculation 

Y09-310 (AC-DC) Battery Operated Laser Particle Counter
The Model Y09-310AC-DC (Battery Operated) Laser Particle Counter is used to detect the particles in the cleanroom. It can measure the class 100 to 300 k environment. The instrument uses the laser diode as the light source, LCD-panel displays, six different size ranges simul taneously. The built-in printer can print count results. The counter can store 1000 samples data. Software creates data files for viewing or export to EXCEL sheet to computer. The instrument is widely used in the fields of micro-electronics, precision machinery, optics, pharmacy and sanitation, biology, food and beverage, aerospace and so on.
 
 Specifications

Outside Dim
300*360*126 mm3; (Wide*Deep*High)
Weight7.5Kg
Max. Consumption48W
Power SourceDC 16.8V (Lithium Ion Battery)
Size Channels0.3, 0.5, 1, 3, 5, 10 μm
Calculation95%UCL calculation, Display Particle Concentration
Flow Rate28.3L/min (Imported Pump)
Sample Time1---10min (Selectable)
Zero Count10min
Location Labels0-999
PrinterBuilt-in Thermal Printer
Alarm10,100, 1000, 10000 ,100000,300000Class /ISO
Data Storage1000 Samples (With PC Software)
Light SourceLaser Diode (30, 000 hours Mean Time Between Failures)
Maximum Rated Particle Concentration35000 particles/L
Operating Time3 hours
Environmental Temperature10degrees celsius-35degrees celsius
Humidity20%-75%RH
Atmosphere Pressure86Kpa-106Kpa
 
 




























  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$4000.00 1 Piece(MOQ)

Y09-310 (AC-DC) Battery Operated Laser Particle Counter

Zhejiang FUXIA Medical Technology Co., Ltd.
$1100.00 1 Piece(MOQ)

Sugold Laboratory 500 Degree High Temperature Drying Oven

Zhejiang FUXIA Medical Technology Co., Ltd.
$1900.00 1 Piece(MOQ)

Lab Class 100 Vertical Biological Safety Cabinet

Zhejiang FUXIA Medical Technology Co., Ltd.
$700.00 1 Piece(MOQ)

Fkc-1 Type Microbiological Air Sampler

Zhejiang FUXIA Medical Technology Co., Ltd.
$699.00 1 Piece(MOQ)

Total Suspended Solids Meter Sensor Monitor Waste Water Tss Real Time Monitoring

Shanghai Boqu Instrument Co., Ltd.
$58.00 1 Piece(MOQ)

Gc01 Radioactivity Nuclear Radiation Detector Geiger Counter Dosimeter

Shenzhen Slinya Electronic Co., Ltd.
$150.00 1 Piece(MOQ)

2152 Ross-Miles Powder Detergent Liquid Detergent Soap Foaming Test Apparatus Surface Active Agent Analyzer

Foshan Henwi Technology Co., Ltd
$70.00 1 Piece(MOQ)

High End Lux Meter Light Meter with Data Logging Factory OEM ODM Manufacturer

Leeder Technology Holdings Limited
$495.00 1 Piece(MOQ)

Lab Analysis Instruments Jy-Zy7 Trans-Blot Cell, Electrophoresis Intruments

Beijing JUNYI Electrophoresis Co., Ltd.
$1000.00 1 Piece(MOQ)

Medical Equipment Hematology Analyzer Price

Nanjing Mineddy Medical Equipment Co., Ltd.