300A 4-20mA DC 4V Hall Effect Current Sensor for DC Screen
| Price | $10.60 |
|---|---|
| Min Order | 10 Pieces |
| Availability | In Stock |
| Shipping From | Zhejiang, China |
| Popularity | 437 people viewed |
Model NO.:
C1X
Type:
Hall Type
Output Signal Type:
Analog Output
Production Process:
SemiConductor Integrated
Material:
Mixture
Accuracy Grade:
0.5G
Application:
Switching Power Supply
IP Rating:
IP65
Certification:
ISO
Customized:
Customized
Output:
Analog Sensor
Usage:
Hall Sensor
Theory:
Hall Sensor
Supply Voltage:
+-12, +-15
Power Consumption:
<25
Offset Voltage:
@IP=0 +-20
Magnetic Offset:
@IP=+-Ipn-0 +-20
Galvanic Isolation:
@ 50Hz, AC, 1min 2.5
Isolation Resistance:
@ DC 500V 1000
Courier:
DHL, TNT, FedEx
Trademark:
HEYI
Transport Package:
Export and Air-Worthy Standard Carton
Specification:
IEC 6044-1
Origin:
Liushi, Yueqing, Zhejiang Province, China
HS Code:
8542390000
Product Description
C1X series hall effect current sensor is an open loop device based on the measuring principle of the hall effect, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.
·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15V 2:-15V 3:V0UT 4:0V
1. When the current will be measured goes through a sensor, the voltage will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.
·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000
| Electrical data (Ta=25ºC±5ºC,RL=2KΩ,CL=10000PF) |
| Type | C1X-100A | C1X-200A | C1X-300A | C1X-400A | C1X-500A | Unit |
| Rated current(Ipn) | ±100 | ±200 | ±300 | ±400 | ±500 | A |
| Measure range(Ip) | 0-±200 | 0-±400 | 0-±600 | 0-±800 | 0-±1000 | A |
| Rated output | @Ip=±Ipn ±4±1% | V | ||||
| Supply voltage | ±12,±15 | V | ||||
| Power Consumption | <25 | mA | ||||
| Offset voltage | @Ip=0 ±20 | mV | ||||
| Magnetic offset | @Ip=±Ipn-0 ±20 | mV | ||||
| Offset drift | @ -40~+85ºC ≤±1 | mV/ºC | ||||
| Output drift | @ -40~+85ºC ≤±1 | mV/ºC | ||||
| Linearity | @Ip=0-±Ipn ≤1 | %FS | ||||
| Response time | @50A/μS, 10%-90% ≤5 | μs | ||||
| Galvanic isolation | @ 50HZ,AC,1min 2.5 | KV | ||||
| Isolation resistance | @ DC 500V 1000 | MΩ | ||||
| Applications |
·Variable speed drives
·Welding machine
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Electrochemical
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
3. Elucidation: 1:+15V 2:-15V 3:V0UT 4:0V
| Directions for use |
1. When the current will be measured goes through a sensor, the voltage will be measured at the output end.(Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.
| Standards |
·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000
| General date |
| Value | Unit | |
| Operating temperature(TA) | -40 to +85 | ºC |
| Storage temperature(TS) | -40 to +125 | ºC |
| Mass(approx) (M) | 78 | g |
- Similar Products
$75.00
1 Piece (MOQ)
500A Input Measurement Voltage Current Transducer
Hubei Tianrui Electronic Co., Ltd.
$18.00
10 Pieces (MOQ)
Slim Split Core Current Transformer Cts 150A 50mA
Jiangyin Spark Electronic Technology Co., Ltd.
$29.00
10 Pieces (MOQ)
D-C2t High Accuracy Hall Current Sensor 100A Open Loop Mode
Wenzhou Heyi Electrical Co., Ltd.
$90.00
1 Piece (MOQ)
1200A/0.333V Flexible Current Transformer
Jiangyin Spark Electronic Technology Co., Ltd.