Swipe or use the arrows to view product images.
Eaton Steering Priority Valve Vlc-60 881-2203-030 Vlc-60 880-4455
| Price | $550.00 |
|---|---|
| Min Order | 2 pieces |
| Availability | In Stock |
| Shipping From | Guangdong, China |
| Popularity | 385 people viewed |
Model NO.:
VLC, VLE and VLH Hydraulic valve
Temperature:
Depend on Model
Standard:
Standard
Connection Mode:
Depend on Model
Power:
Depend on Product
Material:
Cast Iron
Type:
Depend on Model
Valve Type:
Directional Control Valve
Warranty:
1 Year
Maximum Pressure:
Depend on Product
Keyword:
Vlc, Vle and Vlh
After-Sales Service Provided:
Online Support
Maximum Flow Rate:
Depend on Product
Pressure:
Depend on Product
Weight:
14.7
Product Name:
Hydraulic Valve
Delivery Time:
7--14 Days
Package:
Wooden Box
Structure:
Depend on Product
Application:
Construction Machinery
Trademark:
EATON VICKERS
Transport Package:
Carton Box+Wooden Case
Specification:
56X45X55cm
Origin:
Guangdong, China
Product Description
Eaton Steering Priority Valve VLC-60 881-2203-030 VLC-60 880-4455
Hydraulic Pump | Cylinder Block | Press Pin | Valve Plate | Barrel Washer |
Piston Motor | Piston Shoe | Snap Ring | Shoe Plate | oil Seal |
Piston Pump | Retainer Plate | Coil Spring | Bearing Plate | Frication Plate |
Gear Pump | Ball Guide | Disk Spring | Swash Plate | Steel Plate |
Eaton Vickers VLC, VLE and VLH valves are load sensing priority valves. They provide reliable flow based on the need for
steering, braking, or other priority functions, while allowing excess flow to be used for auxiliary functions.
Eaton priority valves can be used with open-heart, closed-center, or load-sensing systems. They can be used with fixed
displacement pumps in open-center systems or with pressure-compensated pumps in closed-center systems.
There are two types of load sensing signal systems: static and dynamic. In a static signaling system, the pump and priority valve
sense the static pressure in the sensing line. Static signal systems are used in traditional applications where response or
circuit stability is not an issue. In a dynamic signaling system, pumps and priority valves sense the pressurization in the load
sensing line caused by the spring and the small amount of flow from the control flow line through the dynamic signal orifice. Used
with fixed or variable displacement pumps, the dynamic signaling system offers a variety of benefits, including faster steering
response, improved cold-weather start-up performance, and enhanced flexibility to optimize system performance and stability.
Eaton's load sensing priority valves are available in 3 sizes:
The Eaton Vickers VLC is rated at 276 bar (4,000 psi) and has a flow rate of 60 l/min;
VLE rated at 310 bar (4,500 psi) for EF ports and 276 bar (4,000 psi) for CF ports with 150 l/min flow;
EF port rated for 297 bar (4,300 psi)VLH and the CF port is rated for 276 bar (4,000 psi) with a flow rate of 240 l/min.
Please contact us for more technical details and configuration options.
steering, braking, or other priority functions, while allowing excess flow to be used for auxiliary functions.
Eaton priority valves can be used with open-heart, closed-center, or load-sensing systems. They can be used with fixed
displacement pumps in open-center systems or with pressure-compensated pumps in closed-center systems.
There are two types of load sensing signal systems: static and dynamic. In a static signaling system, the pump and priority valve
sense the static pressure in the sensing line. Static signal systems are used in traditional applications where response or
circuit stability is not an issue. In a dynamic signaling system, pumps and priority valves sense the pressurization in the load
sensing line caused by the spring and the small amount of flow from the control flow line through the dynamic signal orifice. Used
with fixed or variable displacement pumps, the dynamic signaling system offers a variety of benefits, including faster steering
response, improved cold-weather start-up performance, and enhanced flexibility to optimize system performance and stability.
Eaton's load sensing priority valves are available in 3 sizes:
The Eaton Vickers VLC is rated at 276 bar (4,000 psi) and has a flow rate of 60 l/min;
VLE rated at 310 bar (4,500 psi) for EF ports and 276 bar (4,000 psi) for CF ports with 150 l/min flow;
EF port rated for 297 bar (4,300 psi)VLH and the CF port is rated for 276 bar (4,000 psi) with a flow rate of 240 l/min.
Please contact us for more technical details and configuration options.
Q: ARE YOU A TRADING COMPANY OR A FACTORY?
A:It Is A Trading Company With Professional Engineers,and Our Own Factory Produces Hydraulic Products.if You Have Any Questions.please Feel Free To Contact Us For More Details
Q:WHAT IS THE DELIVERY TIME FOR YOUR PRODUCTS?
A: It Depends On Whether The Product You Buy Is Instock Or Not.if It Is In Stock,we Will Ship Within 3-5 Days.if Not,it Will Be Determined By The Factory Production Time.
Q:WHAT IS THE WARRANTY PERIOD FOR YOUR PRODUCTS?
A: One Year After Shipment
Q: IF THE PRODUCT DOES NOT MEET THE REQUIREMENTS,HOW CAN ISOLVE THEPROBLEM?
A: We Will Send Specific Models And Drawings (if Required) For You Toconfirm Before You Start Ordering.
Q:DOES YOUR COMPANY ACCEPT CUSTOMIZATION?
A: Yes,We Accept OEM.
Q:WHAT'S BRAND YOU CAN OFFER IN YOUR COMPANY?
A: 1) OEM, 100% Genuine Parts, Copy(made In China). 2) Genuine Parts.
Q:WHAT'S PACKAGE? CAN YOU GIVE ME THE PACKAGE ACCORDING MY REQUIREMENT?
A: Yes, Original packing or Neutral packing with wooden box or carton.
- Similar Products
$3000.00
1 Set (MOQ)
Dense Phase Rotary Valve for Cement Industry
Changzhou Fuwei Machinery Co., Ltd.