AMC100 series precision powerdistribution monitoring devices are applied to IDC data centers such as finance, operators,governments, IT, etc. The product can be flexibly configuredreal-time monitoring and centralized management of thepower consumption of the entire data center.
Instrument model | AMC100-ZA | |
Measurement parameters | Voltage, current, frequency, active power, reactive power, power factor, active energy, reactive energy, Zero-to-ground voltage, leakage current and zero sequence current, total harmonic content (THD), 2-63 harmonics, current and voltage unbalance, ambient temperature and humidity | |
Bus voltage | Rated | 220VAC |
Measuring range | ±20% | |
Overload | Instantaneous voltage 2 times/sec | |
Current incoming circuit | Rated | Secondary 5A |
Range | 0~6A | |
Overload | Continuous 1.2 times, instantaneous 10 times/sec | |
Temperature and humidity | Temperature Range | -40ºC~+99ºC |
Humidity Range | 20%~90% |
Input frequency | AC45~65Hz | |
Measurement accuracy | Incoming line | Voltage/current level 0.2, active power/energy level 0.5, reactive power/energy level 1 |
Temperature | ±1ºC | |
Humidity | ±5% | |
Auxiliary power | AMC100-ZA: signal to take power (≤15W) AMC100-ZA-P220: 220V independent power supply AMC100-ZA-P24: 24V independent power supply | |
Environment | Temperature | Work: -20ºC~150ºC Storage: -25ºC~70ºC |
Humidity | Relative humidity≤93% | |
elevation | ≤2500m | |
Switch output | 4 channels 3A 250VAC/3A 30VDC | |
Switch input | 8 dry nodes | |
Communication | 1 isolated RS485/Modbus-RTU to the background system 1 RS485/Modbus-RTU to touch screen 1 RS485/Modbus-RTU connection downstream module Optional 1-channel Ethernet communication function | |
Installation Method | DIN35mm rail or bottom plate installation | |
Protection level | IP20 | |
Pollution level | 2 | |
Security | Insulation | The insulation resistance between all terminals and the conductive parts of the shell is not less than 100MΩ |
Withstand voltage | A voltage and current signal//B voltage and current signal//switch output//isolated communication port//between other ports meet AC2kV 1min, switch input and other ports should meet AC0.5kV 1min, leakage current Should be less than 2mA, no breakdown or flashover phenomenon. | |
Electromagnetic compatibility | Anti-static interference | Level 4 |
Anti-electric fast transient burst | Level 3 | |
Anti-surge interference | Level 4 | |
Resistance to radio frequency electromagnetic field radiation | Level 3 |