1.1. The heating surface adopts closely packed circular coils, the heating surface is arranged adequately, and multiple return heat exchange is performed.
1.2. The furnace size matches the combustion flame, and the radiation heat exchange efficiency is high.
1.3. Positive pressure combustion is adopted to greatly improve its combustion efficiency.
1.4. Closed-circuit heating, no waste heat discharge, and high thermal efficiency.
1.5. The boiler adopts high-quality insulation materials and special construction technology, with less heat loss, low exhaust temperature, and high boiler thermal efficiency.
1.6. The heating surface is arranged reasonably and the boiler starts quickly.
1.7. Energy saving, low cost of use, and the entire investment can be recovered in only 6-9 months.
2. Safe and reliable
2.1 The heating surface adopts closely packed circular coils, and the heating surface is arranged adequately, which effectively reduces the heat load on the tube surface and makes the use of heat transfer oil safer.
2.2 The boiler operation can be remotely monitored and near-ground monitored, with complete automatic control and detection instruments, safe and reliable, and easy to operate.
Gas (oil) thermal oil furnace parameter table | ||||||||||
Modal | Unit | YYW-350YQ | YYW-600YQ | YYW-900YQ | YYW-1200YQ | YYW-1500YQ | YYW-1800YQ | YYW-2300YQ | YYW-2900YQ | |
Rated thermal power | MW | 0.35 | 0.6 | 0.9 | 1.2 | 1.5 | 1.8 | 2.3 | 2.9 | |
Kal/h | 300,000 | 500,000 | 750,000 | 1,000,000 | 1,300,000 | 1,500,000 | 20,000,000 | 2,500,000 | ||
Rated working pressure | Mpa | 0.8 | ||||||||
Boiler design thermal efficiency | % | ≥92 | ||||||||
Maximum operating temperature | ºC | 320 | ||||||||
Medium circulation volume | m³/h | 40 | 58 | 100 | 100 | 100 | 160 | 160 | 200 | |
Import caliber | DN | 100 | 100 | 125 | 125 | 125 | 150 | 150 | 200 | |
Outlet diameter | DN | 100 | 100 | 125 | 125 | 125 | 150 | 150 | 200 | |
System installed capacity | KW | 10 | 15 | 28 | 36 | 44 | 54 | 50 | 60 | |
Design fuel | Oil and gas | |||||||||
Furnace medium capacity | M³ | 0.4 | 0.6 | 0.6 | 0.8 | 1.2 | 2.1 | 2.6 | 3.5 | |
Fuel consumption | 0# Light diesel | kg/h | 36 | 64 | 89 | 125.6 | 155 | 164 | 246 | 292 |
Natural gas | Nm³/h | 45 | 75 | 108 | 153.4 | 188 | 173 | 302 | 344 | |
Shipping Weight | KG | 1300 | 4000 | 5300 | 5600 | 7300 | 8700 | 13700 | 15.2 | |
Dimensions | Length | mm | 1600 | 2000 | 3400 | 3500 | 4600 | 4700 | 5200 | 5400 |
Width | mm | 1500 | 1800 | 1900 | 2200 | 2300 | 2500 | 2800 | 2800 | |
Height | mm | 1800 | 2000 | 2100 | 2300 | 2400 | 2600 | 2650 | 2800 | |
Modal | Unit | YYW-3500YQ | YYW-600YQ | YYW-900YQ | YYW-1200YQ | YYW-1500YQ | YYW-1800YQ | YYW-2300YQ | YYW-2900YQ | |
Rated thermal power | MW | 3.5 | 4.8 | 5.8 | 7.0 | 8.2 | 9.4 | 10.5 | 14 | |
Kal/h | 3,000,000 | 4,000,000 | 5,000,000 | 6,000,000 | 7,000,000 | 8,000,000 | 9,000,000 | 12,000,000 | ||
Rated working pressure | Mpa | 0.8 | ||||||||
Boiler design thermal efficiency | % | ≥92 | ||||||||
Maximum operating temperature | ºC | 320 | ||||||||
Medium circulation volume | m³/h | 200 | 260 | 300 | 340 | 400 | 520 | 600 | 680 | |
Import caliber | DN | 200 | 200 | 250 | 250 | 250 | 300 | 300 | 350 | |
Outlet diameter | DN | 200 | 100 | 250 | 250 | 250 | 300 | 300 | 350 | |
System installed capacity | KW | 60 | 85 | 100 | 120 | 140 | 170 | 195 | 250 | |
Design fuel | Oil and gas | |||||||||
Furnace medium capacity | M³ | 7.8 | 8.4 | 8.8 | 10.5 | 11.2 | 11.5 | 13 | 18 | |
Fuel consumption | 0# Light diesel | kg/h | 356 | 457 | 570 | 686 | 801 | 916 | 1085 | 1375 |
Natural gas | Nm³/h | 432 | 554 | 693 | 832 | 973 | 1113 | 1310 | 1670 | |
Shipping Weight | KG | 20100 | 29.2 | 37300 | 47500 | 54000 | 58600 | 65500 | 108800 | |
Dimensions | Length | mm | 6200 | 6800 | 7400 | 7800 | 8000 | 8500 | 8800 | 11200 |
Width | mm | 2900 | 3200 | 3300 | 3400 | 3500 | 3600 | 3800 | 3800 | |
Height | mm | 2800 | 3300 | 3400 | 3500 | 3600 | 3700 | 3900 | 3900 |