2,Safety is guaranteed: including temperature sensors, water level controllers, pressure gauges, safety valves, explosion-proof doors, etc. The digital control system monitors and maintains the normal working state of the boiler.
4,The reheat chamber adopts butt welding technology and wet back structure, which avoids the disadvantage of overheating and deformation of the parent material caused by the scouring of high-temperature flue gas on the rear tube plate, ensuring the safe operation of the boiler.
5,The outer packaging material adopts electrostatic spray cold plate. Compared with the paint type outer packaging or color steel plate packaging, it has the characteristics of strong corrosion resistance, beautiful appearance, no paint explosion, and long-lasting.

Horizontal gas-fired atmospheric pressure hot water boiler (120 mg) parameter table | ||||||||||
Modal | Unit | CWNS0.35-85/60-Q.Y | CWNS0.47-85/60-Q.Y | CWNS0.58-85/60-Q.Y | CWNS0.7-85/60-Q.Y | CWNS0.94-85/60-Q.Y | CWNS1.05-85/60-Q.Y | CWNS1.2-85/60-Q.Y | CWNS1.4-85/60-Q.Y | |
Rated thermal power | MW | 0.35 | 0.48 | 0.58 | 0.7 | 0.94 | 1.05 | 1.2 | 1.4 | |
Rated heat output | Kal/h | 300,000 | 400,000 | 500,000 | 600,000 | 800,000 | 900,000 | 1,000,000 | 1,200,000 | |
Rated working pressure | Mpa | 0 | ||||||||
Outlet/return water temperature | ºC | 85/60 | ||||||||
Boiler design thermal efficiency | % | ≥96 | ||||||||
Heating area | M² | 11.7 | 16.6 | 16.6 | 19.64 | 33.5 | 35.3 | 32.92 | 39.59 | |
Steel furnace water capacity | m³ | 0.98 | 1.46 | 1.47 | 1.95 | 2.02 | 2.22 | 2.85 | 2.85 | |
Flue size | mm | Ф250 | Ф280 | Ф280 | φ350 | 400*280 | 400*280 | φ370 | 520*310 | |
Water return diameter | DN | 65 | 80 | 80 | 100 | 100 | 100 | 100 | 125 | |
Water outlet diameter | DN | 65 | 80 | 80 | 100 | 100 | 100 | 100 | 125 | |
Atmospheric caliber | DN | 65 | 65 | 80 | 80 | 100 | 100 | 100 | 125 | |
Sewage diameter | DN | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | |
Fuel consumption | 0# Light diesel | kg/h | 33.2 | 55.1 | 54.1 | 64.2 | 85.4 | 96.1 | 112.2 | 133.2 |
Natural gas | Nm³/h | 39.8 | 65.8 | 64.2 | 76.9 | 102.5 | 114.5 | 130.8 | 156.8 | |
Shipping Weight | KG | 1300 | 2000 | 1850 | 2600 | 3200 | 3250 | 3250 | 4000 | |
Dimensions | Length | mm | 2200 | 2800 | 2630 | 3000 | 3000 | 3200 | 3100 | 3560 |
Width | mm | 1200 | 1320 | 1350 | 1420 | 1550 | 1550 | 1650 | 1590 | |
Height | mm | 1500 | 1660 | 1680 | 1850 | 1950 | 1945 | 2350 | 2100 | |
Modal | Unit | CWNS1.75-85/60-Q.Y | CWNS2.1-85/60-Q.Y | CWNS2.45-85/60-Q.Y | CWNS2.8-85/60-Q.Y | CWNS3.5-85/60-Q.Y | CWNS4.2-85/60-Q.Y | CWNS5.6-85/60-Q.Y | CWNS7.0-85/60-Q.Y | |
Rated thermal power | MW | 1.75 | 2.1 | 2.45 | 2.8 | 3.5 | 4.2 | 5.6 | 7.0 | |
Rated heat output | Kcal/h | 1,500,000 | 18,00,000 | 2,100,000 | 2,400,000 | 3,000,000 | 3,600,000 | 4,800,000 | 6,000,000 | |
Rated working pressure | Mpa | 0 | ||||||||
Outlet/return water temperature | ºC | 85/60 | ||||||||
Boiler design thermal efficiency | % | ≥96 | ||||||||
Heating area | M² | 52.15 | 58.78 | 70.33 | 76.8 | 95.1 | 128.6 | 168.81 | 278.06 | |
Steel furnace water capacity | M³ | 2.95 | 3.50 | 5.10 | 5.15 | 6.90 | 8.30 | 9.99 | 15.10 | |
Flue size | mm | 500*300 | 600*300 | 680*300 | 660*300 | 680*360 | 800*400 | 1000*490 | 1100*550 | |
Water return diameter | DN | 125 | 150 | 150 | 150 | 150 | 200 | 200 | 250 | |
Water outlet diameter | DN | 125 | 150 | 150 | 150 | 150 | 200 | 200 | 250 | |
Atmospheric caliber | DN | 125 | 125 | 150 | 150 | 150 | 200 | 200 | 250 | |
Sewage diameter | DN | 40 | 40 | 40 | 50 | 50 | 50 | 50 | 50 | |
Fuel consumption | 0# Light diesel | kg/h | 165.5 | 196.0 | 228.7 | 258.3 | 330.5 | 384.1 | 506.4 | 757.2 |
Natural gas | Nm³/h | 193.5 | 234.0 | 190.8 | 309.9 | 388.5 | 463.1 | 610.4 | 625.8 | |
Shipping Weight | KG | 4500 | 5100 | 6550 | 7000 | 8200 | 10000 | 12600 | 16500 | |
Dimensions | Length | mm | 3800 | 4100 | 4370 | 4600 | 5200 | 5600 | 6300 | 7100 |
Width | mm | 1700 | 1700 | 2050 | 1920 | 2100 | 2300 | 2340 | 2800 | |
Height | mm | 2100 | 2300 | 2450 | 2300 | 2550 | 2700 | 2750 | 3100 |
Yellow means that the 2023 edition sample data and drawings are inconsistent and need to be adjusted
Horizontal gas-fired atmospheric pressure hot water boiler (30 mg) parameter table | |||||||||||
Modal | Unit | CWNS0.35-85/60-Q.Y | CWNS0.47-85/60-Q.Y | CWNS0.58-85/60-Q.Y | CWNS0.7-85/60-Q.Y | CWNS0.94-85/60-Q.Y | CWNS1.05-85/60-Q.Y | CWNS1.2-85/60-Q.Y | CWNS1.4-85/60-Q.Y | ||
Rated thermal power | MV | 0.35 | 0.48 | 0.58 | 0.7 | 0.94 | 1.05 | 1.2 | 1.4 | ||
Rated heat output | Kal/h | 300,000 | 400,000 | 500,000 | 600,000 | 800,000 | 900,000 | 1,000,000 | 1,200,000 | ||
Rated working pressure | Mpa | 0 | |||||||||
Outlet/return water temperature | ºC | 85/60 | |||||||||
Boiler design thermal efficiency | % | ≥96 | |||||||||
Heating area | M² | 11.7 | 16.6 | 16.6 | 24.55 | 30.94 | 34.71 | 37.17 | 45.15 | ||
Steel furnace water capacity | M³ | 0.98 | 1.46 | 1.47 | 1.95 | 2.02 | 2.87 | 2.87 | 2.95 | ||
Flue size | mm | Ф250 | Ф280 | Ф280 | Ф350 | 380*280 | 520*310 | 420*300 | 520*310 | ||
Water return diameter | DN | 65 | 80 | 80 | 100 | 100 | 125 | 100 | 125 | ||
Water outlet diameter | DN | 65 | 80 | 80 | 100 | 100 | 125 | 100 | 125 | ||
Atmospheric caliber | DN | 65 | 65 | 65 | 80 | 100 | 100 | 100 | 125 | ||
Sewage diameter | DN | 40 | 40 | 40 | 40 | 40 | 40 | 40 | 40 | ||
Fuel consumption | 0# Light diesel | kg/h | 30 | 36 | 40 | 54.06 | 84.5 | 133.2 | 95 | 127.8 | |
Natural gas | Nm³/h | 34.6 | 58.2 | 59.8 | 76.95 | 103.77 | 156.8 | 120.9 | 153.3 | ||
Shipping Weight | KG | 1700 | 2500 | 2700 | 3870 | 4500 | 3500 | 4500 | 5900 | ||
Dimensions | Length | mm | 2300 | 2900 | 3950 | 3300 | 3400 | 3600 | 3600 | 3800 | |
Width | mm | 1500 | 1620 | 1650 | 1600 | 1600 | 1590 | 1950 | 1850 | ||
Height | mm | 1800 | 1960 | 1980 | 2000 | 1850 | 2100 | 2400 | 2300 | ||
Modal | Unit | CWNS1.75-85/60-Q.Y | CWNS2.1-85/60-Q.Y | CWNS2.45-85/60-Q.Y | CWNS2.8-85/60-Q.Y | CWNS3.5-85/60-Q.Y | CWNS4.2-85/60-Q.Y | CWNS5.6-85/60-Q.Y | CWNS7.0-85/60-Q.Y | ||
Rated thermal power | MW | 1.75 | 2.1 | 2.45 | 2.8 | 3.5 | 4.2 | 5.6 | 7.0 | ||
Rated heat output | Kcal/h | 1,500,000 | 1,800,000 | 2,100,000 | 2,400,000 | 3,000,000 | 3,600,000 | 4,800,000 | 6,000,000 | ||
Rated working pressure | Mpa | 0 | |||||||||
Outlet/return water temperature | ºC | 85/60 | |||||||||
Design thermal efficiency | % | ≥96 | |||||||||
Heating area | M² | 45.0 | 65.3 | 70.33 | 86.2 | 101.3 | 135.6 | 162.8 | 224 | ||
Steel furnace water capacity | M³ | 2.95 | 3.5 | 5.1 | 5.15 | 6.9 | 8.3 | 10.5 | 13.1 | ||
Flue size | mm | 500*300 | 600*280 | 680*300 | 680*280 | 680*360 | 800*490 | 800*450 | 850*400 | ||
Water return diameter | DN | 125 | 150 | 150 | 150 | 150 | 200 | 200 | 200 | ||
Water outlet diameter | DN | 125 | 150 | 150 | 150 | 150 | 200 | 200 | 200 | ||
Atmospheric caliber | DN | 125 | 125 | 150 | 150 | 150 | 200 | 200 | 200 | ||
Sewage diameter | DN | 40 | 50 | 40 | 50 | 50 | 50 | 50 | 2*50 | ||
Fuel consumption | 0# Light diesel | kg/h | 151.25 | 188.5 | 211.75 | 253.6 | 322.5 | 377.5 | 514.3 | 607 | |
Natural gas | Nm³/h | 170.2 | 228.4 | 235.9 | 306.9 | 389.8 | 457.3 | 622.9 | 683 | ||
Shipping Weight | KG | 4900 | 6500 | 6950 | 8000 | 9300 | 12000 | 13650 | 15400 | ||
Dimensions | Length | mm | 3900 | 4550 | 4470 | 5250 | 5300 | 6100 | 6300 | 7050 | |
Width | mm | 2100 | 1920 | 2250 | 2130 | 2250 | 2340 | 2540 | 3000 | ||
Height | mm | 2500 | 2250 | 2650 | 2750 | 2680 | 2750 | 2950 | 3300 |