Model | BKFR-25 | BKFR-35 | BKFR-50 | BKFR-72 | BKFR-120 | ||||||
Rated voltage/frequency | 220V/380V/50Hz | 380V/50Hz | |||||||||
Rated cooling capacity (W) | 2600 | 3500 | 5000 | 7260 | 12000 | ||||||
Rated heat (W) | 2880 | 3900 | 5700 | 8100 | 12500 | ||||||
Input power (P number) | 1P | 1.5P | 2P | 3P | 5P | ||||||
Refrigeration input power/current (W/A) | 742/3.3 | 1015/4.6 | 1432/6.5 | 2200/10 | 3850/7.5 | ||||||
Heating input power/current (W/A) | 798/3.6 | 1190/5.4 | 1690/7.6 | 2600/11.8 | 3800/7.5 | ||||||
Applicable area (m ²) | 10~12 | 13~16 | 22~27 | 27~34 | 50~80 | ||||||
Noise (dB) | indoor | 34.8/38.8 | 36.8/40.8 | 40/45 | 48 | 52 | |||||
outdoor | 49 | 50 | 53 | 56 | 60 | ||||||
Overall dimension (mm) | Indoor unit | 265x790x170 | 275x845x180 | 298x940x200 | 326x1178x253 | 581x1780x395 | |||||
Outdoor unit | 540x848x320 | 596x899x378 | 700x955x396 | 790x980x440 | 1032x1250x412 | ||||||
Control box | 300x500x190 | 300x500x190 | 300x500x190 | 300x500x190 | 250x380x165 | ||||||
Weight (kg) | Indoor unit | 12 | 10 | 13 | 18 | 63 | |||||
Outdoor unit | 11 | 41 | 51 | 68 | 112 | ||||||
Control box | 10 | 7 | |||||||||
Length of connecting pipe | 4 | ||||||||||
Explosion proof sign | Ex db eb ib mb IIB T4 Gb,Ex db eb ib mb IIC T4 Gb | ||||||||||
Maximum outer diameter of incoming cable | Φ10~Φ14mm | Φ15~Φ23mm |
Split explosion-proof air conditioning treatment
2. A variety of explosion-proof forms are used outside the explosion-proof indoor unit and outdoor unit, and the intrinsically safe explosion-proof circuit is used for the weak current control part.
Security Level: IP66,WF2,Ex db eb ib mb IIB T4 Gb,Ex db eb ib mb IIC T4 Gb
Alias: Explosion Proof Air Conditioner,Ex Proof Air Conditioner
Function: Refrigeration And Heating In Flammable And Explosive Environments
Applicable Scope: Zone 1, Zone 2, Zone 21,Zone 22;IIA, IIB,IIC Explosive Gas Environments
English Standards: 9000 But, 12000 But, 18000 But, 27000 But, 45000 But

2. Explosion proof air conditioners can be divided into: split wall mounted type and floor mounted type according to structure, and can be divided into: single cold type and cold and warm type according to function.
3. The connection of explosion-proof air conditioner pipeline is consistent with that of ordinary air conditioner. The electrical connection must be in accordance with the requirements of explosion-proof electrical installation process. The power supply must be introduced into the explosion-proof control box first, and then divided from the explosion-proof control box. Do not introduce the indoor unit and outdoor unit.
4. The explosion-proof control box is equipped with a power switch.
5. Steel pipe or cable wiring is acceptable.







2. Suitable for IIA, IIB and IIC explosive gas environment;
3. Applicable to T1~T6 temperature groups;
4. It is applicable to dangerous environments such as oil exploitation, oil refining, chemical industry, gas station, offshore oil platforms, oil tankers and metal processing;
5. It is used for temperature regulation in workshops, control rooms, laboratories and other fields.









A: Can I have a sample order?
Thanks for your visiting and hope to cooperate!! ($10 free for the first order) |
contact us
Company: Shenhai Explosion-Proof Technology Co., Ltd.
Address:
RM.1204, Lanjue International Centre, No.358 Jincheng Rd., Xiaoshan Dist., Hangzhou CY, Zhejiang Prov., P.R.C. (P.O.: 311202)
No. 318, Wei15 Road,Yueqing Economic Development Zone, Wenzhou, Zhejiang, China.