TD1600 AC Source for AC Current Meter Voltage Meter Calibration

Price $999.00 Compare
Min Order 1 Piece
Availability In Stock
Shipping From Hunan, China
Popularity 286 people viewed
Quantity
+-
 

Tunkia Co., Ltd.

VIP   Audited Supplier 5 years
Profile Certified by SGS/BV
  • Hunan, China
  • Eugene (Mr.)  
    Overseas Dept. Director
TD1600
24h
365 Days
Chemical Instrument, Thermal Power, Mechanical Instrument, Length Instrument, Time Frequency Instrument, Electromagnetic Instrument, Radio Apparatus
Electricity
CCC
1100V(MAX)
110A(MAX)
With LCD Display
Customized
45 Hz ~ 70 Hz
TUNKIA
China
Product Description
TD1600 Precision AC Calibrator


Introduction
  1. TD1600, a single-phase AC calibrator with wide range, high precision and multifunction.
  2. The apparatus can output high accuracy AC voltage, current and power, and the optional accuracy are 0.05% and 0.02%. Applied to calibrate various AC electrical measuring instruments.

Features
  1. AC Electrical Parameter Output: Voltage is up to 1100 V, current is up to 110 A.
  2. Frequency and Phase Adjustment: Frequency: 45 Hz ~ 70 Hz.
  3. AC Power Output: Measure the active power, reactive power, apparent power and power factor.
  4. Value Output Mode: Standard source and output source modes, easy to calibrate both digital meters and analogue meters.
  5. Value Adjustment Method: Fixed-point, rotary encoder, step and potentiometer (option).
  6. Output Switch: The output can be turned on/off arbitrarily by one-touch operation.
  7. Automatical Error Calculation: Set the measured values of the checked meter, and adjust the value output to automatically calculate the errors of the checked meter.
  8. Excellent Human-computer Interaction: Large LCD touch screen display, touch and button operation modes, easy for users to measure manually.
  9. Harmonic (Option): Load 2nd to 31st harmonics with variable amplitude and phase for impact test.
  10. Proprietary Software (Option): Support the calibration of the checked meters by semi-automatic or full-automatic, data management and report export.

Specification
AC Voltage Output
RangeStability (%/min)Accuracy (k = 2)
(ppm*RD + ppm*RG)
Max. Load Current
(mA)
0.05%0.02%0.05%0.02%
1 V0.010.005300 + 200120 + 80500
3 V0.010.005300 + 200120 + 80500
10 V0.010.005300 + 200120 + 80500
30 V0.010.005300 + 200120 + 80500
60 V0.010.005300 + 200120 + 80800
100 V0.010.005300 + 200120 + 80500
150 V0.010.005300 + 200120 + 80400
200 V0.010.005300 + 200120 + 80250
300 V0.010.005300 + 200120 + 80150
400 V0.010.005300 + 200120 + 80100
600 V0.010.005300 + 200120 + 8080
750 V0.010.005300 + 200120 + 8060
1000 V0.010.005300 + 200120 + 8050

AC Current Output
RangeStability (%/min)Accuracy (k = 2)
(ppm*RD + ppm*RG)
Max. Inductive
Load (V)
0.05%0.02%0.05%0.02%
1 mA1 μA0.5 μA300 + 2 μA120 + 1 μA120
2 mA1 μA0.5 μA300 + 2 μA120 + 1 μA120
5 mA1 μA0.5 μA300 + 2 μA120 + 1 μA120
10 mA0.010.005300 + 200120 + 80120
20 mA0.010.005300 + 200120 + 80120
50 mA0.010.005300 + 200120 + 80120
100 mA0.010.005300 + 200120 + 80120
200 mA0.010.005300 + 200120 + 80120
500 mA0.010.005300 + 200120 + 80100
1 A0.010.005300 + 200120 + 8050
2 A0.010.005300 + 200120 + 8025
5 A0.010.005300 + 200120 + 8010
10 A0.010.005300 + 200120 + 805
20 A0.010.005300 + 200120 + 802.5
30 A0.010.005300 + 200120 + 802.5
50 A0.010.005300 + 200120 + 801.5
100 A0.010.005300 + 200120 + 800.8

Output Characteristics of Voltage and Current
  1. Output Range of Voltage: 100 mV ~ 1100 V
  2. Output Range of Current: 0.1 mA/ 20 mA ~ 110 A
  3. Range Switching: Automatic or Manual.
  4. Resolution: 0.001 %*RG; Display: 6 digits; Distortion: <0.2 %
  5. 1 mA,2 mA,5 mA are small range option.

Frequency, Phase and Harmonic (Option)
TypeRangeResolutionAccuracy
Frequency45.000 Hz ~ 70.000 Hz0.001 Hz0.005 Hz
Phase0.0000 ° ~ 359.9999 °0.005 °0.05 °
TypeOrderAmplitudeVariable Phase
Harmonic2nd to 31st0 ~ 25 %0 ~ 359.9 °

Power Output
TypeStability (%/min)Accuracy (k = 2) %*FS
0.05%0.02%0.05%0.02%
Active Power0.010.0050.050.025
Reactive Power 0.020.010.10.05
Apparent Power0.020.010.10.05
Power Factor0.020.010.10.05
  1. Output Range of AC Power: Combination of AC voltage range and AC current range.
  2. Range of Power Factor: -1.0000…0.0000…+1.0000
  3. Active Power (|cosφ| ≥0.5), Reactive Power (|sinφ| ≥0.5)

Company Profile
 





  • Contact Supplier
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA  
$100000.00 1 Set(MOQ)

TUNKIA TK4830 CCS2 Type2 AC DC EV Charger Tester Charing Staion Tester

Tunkia Co., Ltd.
$75000.00 1 Piece(MOQ)

Digital Electrical Multifunction Instrument 6.5 digit Multimeter Calibrator

Tunkia Co., Ltd.
$100000.00 1 Piece(MOQ)

TS1200 Electrical Steel cold rolled steel silicon steel AC Magnetic Field Measurement Equipment

Tunkia Co., Ltd.
$81000.00 1 set(MOQ)

TA1200 High Frequency Transconductance Amplifier

Tunkia Co., Ltd.
$497.00 1 Piece(MOQ)

Aileike Alkt511 Micro Pressure Calibration Table Pressure Calibrator -1~6 Bar

Aileike TT&C Equipment (Huaian) Co., Ltd.
$1500.00 1 Piece(MOQ)

H+W Intelligent High Accuracy Dry Block Temperature Calibrator

Universky (Jiangsu) Technologies Co., Ltd.
$200.00 1 Piece(MOQ)

Marine Anti-piracy Digital Night Vision Binoculars Camera HD 720p Telescope

Universky (Jiangsu) Technologies Co., Ltd.
$2300.00 1 Piece(MOQ)

Ckt3800-1200 Dry Block Temperature Calibrator Calibration Furnace 300c~1200c

Changzhou Chuangkai Electronic Co., Ltd.
$5500.00 1 Piece(MOQ)

Dry Block Calibrator Temperature Calibrators Dry Well

Beijing Spake Technology Co., Ltd.
$5000.00 1 Set(MOQ)

Three Phase Energy Meter Test Field Calibrator

Beijing GFUVE Electronics Co., Ltd.