Swipe or use the arrows to view product images.
10kv 24kv Outdoor Load Break Isolation Medium High Voltage Disconnector Load Break Disconnect Switch Isolator
| Price | $130.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Zhejiang, China |
| Popularity | 278 people viewed |
Model NO.:
(H)GW9
Type:
High-voltage
Structure:
Three-column Disconnector
Installation:
Outdoor High-voltage
Operation:
Electric
Grounding Mode:
Grounding
Movement Mode:
Horizontal Rotary Type
Number of Poles:
Three Pole
Structure of Operating:
Electric
Certification:
ISO, IS9001, ISO9002, ISO2000
Rated Frequency:
50Hz
Rated Voltage:
12kv
Rated Current:
630(1250)a
Rated Peak Withstand Current:
20(25)/4ka/S
Trademark:
DGG
Transport Package:
Export Box
Origin:
China
HS Code:
853530900
Product Description
Our factory
We are professional manufacturer of current transformer ,voltage transformer, Vacuum Circuit Breakers/Recloser,Isolation switches,Dropout Fuse Cut-out,Lightning Arresters,High and Low Voltage Cabinets,Metering Devices,Power Distribution Transformers etc.
General
The "(H)GW9-12" outdoor high voltage switch equipment of single phase AC 50Hz.The product is suitable for power systems with a rated voltage of 10kV to make or break power supply under circumstances of voltage and no load. The isolator adopts an isolated hook rod to operate.
Service conditions
1. The altitude does not exceed 1000m.
2. The ambient air temperature: Maximum:+40ºC; Minimum:-30ºC, Paramos:-40ºC
3. The wind pressure does not exceed 700Pa.(corresponding to 34m/s wind speed).
4. The earthquake intensity does not exceed 8 degrees.
5. The working situation hasn't frequent violent vibration.
6. The installation site of an ordinary type isolator should be kept away from gas, smoke chemical deposition,salt-spray fog, dust, and other explosive and corrosive matters that affect seriously the insulation and conduction capability of the isolator.
7. Pollution-proof type isolator is applied to severe filthy conduction area; however, it shouldn't be any explosive matters and matters causing a fire.
Test Reports
All products have undergone professional testing and certification.
Photos of Product
We are professional manufacturer of current transformer ,voltage transformer, Vacuum Circuit Breakers/Recloser,Isolation switches,Dropout Fuse Cut-out,Lightning Arresters,High and Low Voltage Cabinets,Metering Devices,Power Distribution Transformers etc.
General
The "(H)GW9-12" outdoor high voltage switch equipment of single phase AC 50Hz.The product is suitable for power systems with a rated voltage of 10kV to make or break power supply under circumstances of voltage and no load. The isolator adopts an isolated hook rod to operate.
Service conditions
1. The altitude does not exceed 1000m.
2. The ambient air temperature: Maximum:+40ºC; Minimum:-30ºC, Paramos:-40ºC
3. The wind pressure does not exceed 700Pa.(corresponding to 34m/s wind speed).
4. The earthquake intensity does not exceed 8 degrees.
5. The working situation hasn't frequent violent vibration.
6. The installation site of an ordinary type isolator should be kept away from gas, smoke chemical deposition,salt-spray fog, dust, and other explosive and corrosive matters that affect seriously the insulation and conduction capability of the isolator.
7. Pollution-proof type isolator is applied to severe filthy conduction area; however, it shouldn't be any explosive matters and matters causing a fire.
| Technical parameters | ||||
| No. | Item | Unit | Data | |
| 1 | Rated frequency | Hz | 50 | |
| 2 | Rated voltage | kV | 12 | |
| 3 | Rated current | A | 630(1250) | |
| 4 | Rated short-time withstand current and duration | kA/s | 20(25)/4 | |
| 5 | Rated peak withstand current | kA | 50(63) | |
| 6 | Rated short-time power frequency withstand voltage | Interphase, to earth(dry) | kV/min | 42/1 |
| Interphase, to earth(wet) | 30/1 | |||
| Break(dry) | 48/1 | |||
| Break(wet) | 36/1 | |||
| 7 | Rated lightning impulse withstand voltage | Interphase, to earth | kV | 75 |
| Break | 85 | |||
| 8 | Circuit resistance | μΩ | ≤80 | |
| 9 | Mechanical life | Times | 3000 | |
| 10 | Pollution grade | e class | ||
| 11 | Creepage distance | mm | ≥372 | |
| Note: If the altitude is over 1000m, the rated insulation level should be modified as appropriate. | ||||
Test Reports
All products have undergone professional testing and certification.
- Similar Products
$0.90
1000 Pieces (MOQ)
Modular Changeover Switch 2p 63A Sf263 Sf463
Zhejiang Guoying Electric Co., Ltd
$5000.00
5 Pieces (MOQ)
High Voltage Outdoor Load Break Disconnector Switch
Beierbian Group Co., Ltd
$140.00
1 Piece (MOQ)
Gn30-12, 630 Manual Operation of Three-Phase Disconnector
Zhejiang Maiyu Electric Co., Ltd.
$54.50
100 Pieces (MOQ)
Distribution System Fuse Switch Disconnector
Yueqing Barfuse Electric Co., Ltd.