Menu
Global B2B sourcing platform
Verified suppliers and manufacturers

15kv 600A Single Phase Disconnecting Standard Porcelain Isolate Switch

Price $70.00
Min Order 10 Pieces
Availability In Stock
Shipping From Zhejiang, China
Popularity 363 people viewed
Model NO.:
GW9-15/600
Type:
High-voltage
Structure:
Three-column Disconnector
Installation:
Outdoor High-voltage
Operation:
Manual
Grounding Mode:
Not Grounding
Movement Mode:
Vertical Rotary Type
Number of Poles:
Three Pole
Grounding:
Un Grounded
Series:
Three
Run:
Turn the Horizontal
Switching Mode:
Single Throw-in
Common Model:
Gw9
Structure of Operating:
Manual
Certification:
ISO, ISO9001, IEC
Brand:
Jecsany
Trademark:
Jecsany
Transport Package:
Wooden Carten
Specification:
GW9-15/600
Origin:
China
HS Code:
8535309000
Product Description

Outdoor AC Gang isolator switch 11KV/400A-33KV/1000A used in 3 phase AC 50/60Hz power circuit, it is used as switching on and switch off at the voltage without load. It apply to IEC 60964: 1996, IEC62271-102:2002.         

Type

Unit

HRH-B/11FHRH-B/24FHRH-B/33F

Rated Voltage

KV

11

24

33

Rated Current

A

400

630630

800

630

1250

4s Heat Steady Current

KA

12.5

12.5

12.5

12.5

12.5

12.5

Shock Steady Current

KA

31.5

31.5

31.5

31.5

31.5

31.5

Impulse Withstand Voltage

To Earth

75

75

125

125

170

170

Across the isolating distance

95

95

145

145

195

195

Power frequency withstand voltage

To Earth

38

38

65

65

70

70

Across the isolating distance

42

42

79

79

80

80


Isolating Switch 

An electrical device for the reliable disconnection of certain sections of a high-voltage electrical network when there is no current in them. The use of isolating switches (either alone or in combination with high-speed short-circuiting devices) makes it possible to simplify the arrangement of switching points and transformer substations and to eliminate expensive high-voltage circuit breakers.

 

In the case of damage to certain sections of a network, the circuit breakers operate first, and then the isolating switches automatically disconnect the damaged section, after which the circuit breakers close again and restore electric power to the rest of the consumers on the network. Isolating switches are also used to disconnect and reconnect unloaded transformers and sections of power lines during operation. An isolate switch must provide a reliable connection in case of a random occurrence of a short circuit in the network. An important characteristic of an isolating switch is a short operate time, particularly the disconnect time, which must not exceed 0.1 sec.