15kv Outdoor Isolator High/Medium Voltage Disconnect Switch / Isolator Load Break Disconnect Switch

Price $1500.00
Min Order 1 Piece
Availability In Stock
Shipping From Zhejiang, China
Popularity 480 people viewed
Model NO.:
GW9
Type:
High-voltage
Structure:
Three-column Disconnector
Installation:
Outdoor High-voltage
Operation:
Electric
Grounding Mode:
Grounding
Movement Mode:
Horizontal Rotary Type
Number of Poles:
Three Pole
Structure of Operating:
Electric
Rated Frequency:
50Hz
Rated Voltage:
12kv
Rated Current:
630(1250)a
Rated Peak Withstand Current:
50(63)Ka
Trademark:
DGG
Transport Package:
Export Box
Origin:
China
HS Code:
853530900
Product Description
Our factory

We are professional manufacturer of current transformer ,voltage transformer, Vacuum Circuit Breakers/Recloser,Isolation switches,Dropout Fuse Cut-out,Lightning Arresters,High and Low Voltage Cabinets,Metering Devices,Power Distribution Transformers  etc.

General


The "(H)GW9-12" outdoor high voltage switch equipment of single phase AC 50Hz.The product is suitable for power systems with a rated voltage of 10kV to make or break power supply under circumstances of voltage and no load. The isolator adopts an isolated hook rod to operate.

Service conditions

1. The altitude does not exceed 1000m.
2. The ambient air temperature: Maximum:+40ºC; Minimum:-30ºC, Paramos:-40ºC
3. The wind pressure does not exceed 700Pa(corresponding to 34m/s wind speed).
4. The earthquake intensity does not exceed 8 degrees.
5. The working situation hasn't frequent violent vibration.
6. The installation site of an ordinary type isolator should be kept away from gas, smoke chemical deposition,salt-spray fog, dust, and other explosive and corrosive matters that affect seriously the insulation and conduction capability of the isolator.
7. Pollution-proof type isolator is applied to severe filthy conduction area; however, it shouldn't be any explosive matters and matters causing a fire.

 
Technical parameters
No.ItemUnitData
1Rated frequencyHz50
2Rated voltagekV12
3Rated currentA630(1250)
4Rated short-time withstand current and durationkA/s20(25)/4
5Rated peak withstand currentkA50(63)
6Rated short-time power frequency withstand voltageInterphase, to earth(dry)kV/min42/1
Interphase, to earth(wet)30/1
Break(dry)48/1
Break(wet)36/1
7Rated lightning impulse withstand voltageInterphase, to earthkV75
Break85
8Circuit resistanceμΩ≤80
9Mechanical lifeTimes3000
10Pollution grade e class
11Creepage distancemm≥372
Note: If altitude is over 1000m, the rated insulation level should be modified as appropriate.
 