Swipe or use the arrows to view product images.
Overhead 33kv Mv Gang Opearated 630A ABS Air Break Switches
| Price | $480.00 |
|---|---|
| Min Order | 1 Piece |
| Availability | In Stock |
| Shipping From | Zhejiang, China |
| Popularity | 463 people viewed |
Model NO.:
GW36
Type:
Hv & Mv
Structure:
Double-column Disconnector
Installation:
Outdoor High-voltage
Operation:
Manual
Grounding Mode:
Grounding
Movement Mode:
Plug-in Type
Number of Poles:
Single
Grounding:
Double Ground
Series:
Three
Run:
Vertical Rotation
Common Model:
Gw36
Structure of Operating:
Manual
Certification:
ISO, GS, RoHS, CE, ISO9001
Brand:
L&R
Max. Voltage:
36kv
Product Name:
AC Isolating Switch
Rated Voltage:
36kv
Rated Current:
200A 400A 630A 1000A 1250A
Creepage Distance:
900mm
Trademark:
L&R
Transport Package:
Wooden Pallet
Specification:
GW9-12kV
Origin:
Wenzhou, Zhejiang
HS Code:
8535210000
Product Description
Pole-mounted Air/Load breaker switch
General
The air break switches install in outdoor and mainly use for switching and isolation. The air break switch is mostly installed in the distribution network as a switching point. It interrupts the small excitation current of a transmission line or the capacitive charging current. The maximum voltage for the switches is up to 35kV. The air-break switches are classified into two types. They are Single-Pole Air-Break Switch and the Gang Operated Air-Break Switch
The air break switches install in outdoor and mainly use for switching and isolation. The air break switch is mostly installed in the distribution network as a switching point. It interrupts the small excitation current of a transmission line or the capacitive charging current. The maximum voltage for the switches is up to 35kV. The air-break switches are classified into two types. They are Single-Pole Air-Break Switch and the Gang Operated Air-Break Switch
The (H)GW series outdoor Air/Load breaker switch is a three-phase AC 50Hz /60Hz outdoor medium-voltage switchgear, which can open and close the power line and can see the obvious disconnect distance.
Application voltage levels include 12kV, 24kV and 36kV.
Application standard: IEC62271-102
Technical parameters
| Item | Unit | Data | ||
| Rated voltage | kV | 12 | 24 | 36 |
| Rated frequency | Hz | 50/60 | ||
| Rated current | A | 400 / 630 | ||
| Rated short-circuit withstand/breaking current | kA | 12.5 | ||
| Rated short-circuit making current (peak) | kA | 31.5 | ||
| Rated peak withstand current | kA | 31.5 | ||
| Rated short-circuit time | Sec | 1 | ||
| Mechanical Operations | Times | 5000 | ||
| Power frequency withstand voltage (1 min) | kV | 28/32 | 50/60 | 70/80 |
| Lightning impulse withstand voltage (peak) | kV | 76/85 | 125/145 | 170/190 |